  1. M

    Water In Oil Tank

    I've Oil central heating. My tank is a plastic 1200 ltr ( semi circular type . Titan I think ) feeding a Firebird Popular 90 in the Garage The tanks the same age as the house I guess. 25 years. I have not been getting any problems at all, but just took an inclination last week to buy some water...
  2. M

    BT Master socket and Plug

    Yep, Perfect sense ( I think ) The wires coming from the Face plate are what's feeding all the extensions. They are only fed when the face plates plugged in Thanks again
  3. M

    BT Master socket and Plug

    Just a bit confused. if the blue white - white blue from terminal block are feeding the face plate, what's feeding the terminal block ? shouldn't these to wires come from the Master socket ?
  4. M

    BT Master socket and Plug

    Hi again, Thanks for the links and advice. I'll probably be ordering the item from Run-it-direct which replaces both just in case. I have a cheapo punch down tool as I've just run data cable from my router to dining room tv, and some spare cat 5e. Your last comment "something odd " has spurred...
  5. M

    BT Master socket and Plug

    Hi Thanks I am sure we are on a FTTC connection although a good distance from the cabinet. I have Talktalk Fibre Broad band 35mbs. Max poss speed from cabinet is 20.5mbs and I get 15-17. ADSL or VDSL face plate required or does it make no difference??? Also, with these face plates is it possible...
  6. M

    BT Master socket and Plug

    Wonder If I can get some help. This is my master socket sited on a coat, shoe cupboard ( right under Consumer unit ) as we enter the house. When we bought the house there was a Tel Extension socket in a good few rooms. These have been blanked off as we decorated the house. As you can see on one...
  7. M

    5E data cable run

    All, Thanks for the Input. I don't intend to put it in the same conduit as T&E. And to answer the comment about small cupboard, its actually quite a large space, but the only place I can get a cable through from under the floor and fish it out on the next floor up is where the T&E is routed...
  8. M

    5E data cable run

    Thanks for reply. Problem is that they will have to be right beside each other just for the vertical run in the cupboard. The 2.5mm T&E is in plastic conduit for the run up the cupboard but dunno if this makes any difference
  9. M

    5E data cable run

    Not sure if I should be posting in Computing forum or here. I have to run a Cat5e data cable from my router to Dinning room extension. Part of the run would be through a pantry cupboard from floor through ceiling ( about 2.4m height ) alongside a 2.5mm T&E Radial that only feeds the upstairs...
  10. M

    Re-nailing Roof Tiles / Fitting Eaves felt

    Bit Confused now with "nail down from the top " Don't they clip onto the side channel of the Tile and knock into the 25mm face of the 50 x 25 Batten underneath the tile
  11. M

    Re-nailing Roof Tiles / Fitting Eaves felt

    Don't they knock into the side of the tile supporting Batten ?
  12. M

    Re-nailing Roof Tiles / Fitting Eaves felt

    Thankyou kindly. On order whilst they are only a tenner, Maybe tackle this next summer though
  13. M

    Re-nailing Roof Tiles / Fitting Eaves felt

    Hello again Makie sorry for long delay in sending Photos. Away from home due to work. Heres a couple of photos
  14. M

    Re-nailing Roof Tiles / Fitting Eaves felt

    Hello Makie Can you expand a bit further . Do you mean nail one row and clip the next ??. What type of clips and do they have to be tile type specific ??
  15. M

    Re-nailing Roof Tiles / Fitting Eaves felt

    Just finished capping over my Facia's on the front and back of the house. Still have around the rear extension to do at some later date. The house is a 30 year old Timber framed house with Marley interlocking concrete tiles fitted over under sarking felt. The whole roof has OSB fitted over the...
  16. M

    Dry Verge Bottom tile removal

    Hoping I can get some advice I have to remove this bottom dry verge tile to replace the wood ( or cap over ) behind it. I know that when installing these they are started from the bottom and interlock upwards. Its a Marley type from approx 30 years ago ( that's the age of the house anyway ) In...
  17. M

    Box section steel roofing expansion

    Thanks. Half inch it is
  18. M

    Box section steel roofing expansion

    Hi Going to replace the Box section steel roof on my single slope garage roof. The garage is abutted to the gable end of the house. My question is this. It looks at present like the old roofing sheets ( 5.2m Long ) are abutted hard up against the wall of the house. They are supported by a...
  19. M

    No Hot Water/ Help !!!!

    Update Thanks all for the great help. Rxd new Honeywell V/V and head complete yesterday. ( Its a genuine one ). I'll keep the Valve as a spare. Fitted Head last night and all good again. I promise I'll never release the Hounds on another Plumber ever again
  20. M

    No Hot Water/ Help !!!!

    Hello again So, I took the head off the Mot V/V and checked the spindle. It seems very free, but only swings approx 45 degrees. I didn't want to force it any more. Is this the normal swing on these Honeywell V/Vs ?. The Valve is Honeywell V4043. Next opened up the wiring centre. Bit of a rats...