Search results

  1. The Pars

    Alarm going off when not set Honeywell (securit 800L+)

    When was the panel battery last changed?
  2. The Pars

    Night vision issue

    As above. I had similar problems and by bringing the dome out a bit using a bracket sorted.
  3. The Pars

    Gardtec 800 Series Lost Engineer Code?

    As Sparky says you need a new panel/bell battery. It should be a 7ah but as its diy a 3.2ah will do if you can't get the bigger battery in. To test the bell take out the hold off wire from the panel and bell should ring but you have had full power of and no sound so the bell battery is low. What...
  4. The Pars

    Gardtec 800 Series Lost Engineer Code?

    Depends on the amount of detectors/current draw from the panel when mains is not present. I normally install a 7 amp hour if there is more than 5 PIR's connected in the panel.
  5. The Pars

    Turn Chime on ADT Alarm

    Risco panel went in today @sparkymarka.
  6. The Pars

    Turn Chime on ADT Alarm

    @sparkymarka I sent the shop owner what needed done and the system will not register the chime. He did say that 5&7 flash up on the screen all day so it looks like there is a zone/tamper problem. Would this stop him trying to put chime on zone 1? Now I found out it’s not maintained by ADT so...
  7. The Pars

    Turn Chime on ADT Alarm

    Thanks for the info!
  8. The Pars

    Turn Chime on ADT Alarm

    please can you advise if chime can be turned on from the user menu? Thanks
  9. The Pars

    Deltabell plus external psu

    Yeh the Enforcer can power 1 x Deltabell plus.
  10. The Pars

    Texecom Premier 24 Battery Fault

    Remove battery, switch mains of, turn back on, add battery and reset the system to clear the fault.
  11. The Pars

    help please

    To default I’m sure on power up press reset x2? Then enter default code.
  12. The Pars

    Wireless alarms

    Each installer will have their preferred system but I install Risco Wireless and have done for 10 years with no major issues. We use Orisec bells and I have one of their wireless systems on test and its decent. Just make sure you install 2 way wireless.
  13. The Pars

    Concept remote keypad

    Switch all power to alarm of then back on.Enter your code then install new battery.
  14. The Pars

    Concept remote keypad

    Sounds like it needs a new battery in the panel. Remember to check voltage at battery terminals as this could be faulty if the battery has not been changed in a long time. Should read between 13-13.5v.
  15. The Pars

    Identify ADT Control Panel

    Tbh more or less the same panel and the same procedure replacing the battery.
  16. The Pars

    Identify ADT Control Panel

    No probs. Look up the scantronic 9800 install manual.
  17. The Pars

    Identify ADT Control Panel

    It’s a scantronic alarm installed by ADT. There will be a control panel hidden away somewhere in a cupboard and that is where you need to replace the battery. A yuasa 7Ah battery would be my choice.
  18. The Pars

    Advice on house alarm

    Gardtec cpx has a built in dialler.
  19. The Pars

    PIRs?

    We use Risco I Wise PIR's but have also used Texecom and Optex with no problems. You can still get the Gardscan PIR and ceiling bracket direct from Risco but you have to be in the trade. Im sure amazon sell them.
  20. The Pars

    Risco Alarm add key fob

    You could try 1234 if it’s been left default. Apart from that you would have to contact the installer to either change the code or let him programme the fob in. He will charge a call out but you can have full control of the system if that is what you want. Try 1234 as on the odd occasion this...
Back
Top