Search results

  1. J

    'Evening' mode?

    Thank you. That sounds ideal, however the Flex manual has no reference to a night set feature. Can you point me towards where i can find more information on how to set this feature up? I was intending to use kepyads for setting / unsetting, not fobs.
  2. J

    Smoke detectors

    Hi all, My old intruder alarm system (Galaxy 16+), due for DIY upgrade to a Flex 50 shortly, includes wired smoke detectors, all of which were disabled in the software before we moved in. I'm wondering whether it is better to purchase new detector heads to match the existing (Morley 2351E...
  3. J

    'Evening' mode?

    Hi all, I am upgrading my aged security alarm system following a recent incident when I disturbed burglars. Fortunately, they were even more alarmed than I was and dived out the front window they'd prised open. Because I was home at the time, in the back of the house, the intruder system was...
  4. J

    Smoke detectors on alarm systems

    Thanks all, much appreciated.
  5. J

    Smoke detectors on alarm systems

    Hi, I would like to include smoke detectors and panic buttons as part of my alarm system upgrade. My question is whther these will only operate when the system is armed, or whether modern panels (my system will be based on a Honeywell Flex 50) can be configured to keep detectors and panic...
  6. J

    Honeywell Flex 50 panel upgrade

    That's great, thank you. The firmware is indeed marked on the board (3.39). I know you said it should be 3.51 - so I'm wondering will the board work OK as is, or do I need to find a way to upgrade? Thanks for the advice on the wiring of the sensor and how to use the spare strands. Inside the...
  7. J

    Honeywell Flex 50 panel upgrade

    Thanks for the reply and advice. Attached are pics of the Model 605 keypad, and its rear connections, also the PIR innards and nameplate. You advise adding resistors, presumably one to each PIR. Please can you specify where / how to add, and what value resistor I should use? My new bellbox is...
  8. J

    Honeywell Flex 50 panel upgrade

    Hi all, I have bought a Honeywell Flex050 panel, to replace my old Galaxy 16+ panel, following advice to upgrade from GalaxyGuy several months ago. I am now looking foward to installing it instead of having festive fun (boo hoo). My first question is whether the new panel will be compatible...
  9. J

    Galaxy 16+ "Comm failure"

    Many thanks for the support, GalaxyGuy. I have disabled line voltage, and removed the 0000 account as you suggest. I've not been able to remove the 12345678 DTMF number- I am able to delete it from the display character by character, using the B button as you suggest, but pressing Enter does...
  10. J

    Galaxy 16+ "Comm failure"

    Hi, I am struggling with intermittent internal alarms going off on my ADT Galaxy 16+. These have recently occurred when the alarm has not been set. It is connected to a working domestic telephone line (which I use only for broadband, these days..), but is no longer monitored. When the alarm is...
  11. J

    ADT Galaxy Comms Fail

    Thanks for the reply. Thanks for the suggested alternatives to the old 16+ panel. I will upgrade if I have to.. but I hate waste, and so would prefer to find a solution to the issue than junk and replace the panel, if possible. I have checked that both phone numbers for ADP as well as the...
  12. J

    ADT Galaxy Comms Fail

    Hi all, I have an old Galaxy 16 Plus, no longer monitored by ADP, but connected to a working phone line. Each time the alarm is triggered, I used to get hit with call charges, amounting to a few £ per month, so i decided to try to disable the comms. Following advice from an old thread, I...