  1. F

    ferroli hawk

    heating wont work unless hot tap opened first.then close tap and heating then works.
  2. F

    Help please, basic plumbing/electric question

    why not fit kickspace heaters in your plinth
  3. F

    ravenheat ls80t

    cleaned venturi and washed tube and tested for holes. fan runs at full speed and smooth.
  4. F

    ravenheat ls80t

    i know everyone dislikes these boilers , but someone must have fixed them somewhere , sometime.
  5. F

    Worcester 24 CDI hot water problem

    min gas pressure set too high. should be at about 2mbr
  6. F

    ravenheat ls80t

    boiler pump would run for 30 sec every now and again, nothing else. changed thermistor on heating side which i think is a high limit stat and then linked out flow switch on back of pump. All works after changing flow switch. day after nowt again. pump runs , fan runs , no spark unless i suck on...
  7. F

    Silicone sealant problem

    exterior sealant
  8. F

    baxi 105e

    only going to it on wednesday
  9. F

    baxi 105e

    yea , i know
  10. F

    baxi 105e

    boiler comes on and off to suit itself even when clock(mech) is off , and temp wont reduce on boiler stat.
  11. F

    WORCESTER BOSH GREENSTAR 28i JUNIOR

    this tells me that u either dont have a sufficient bypass on the system or one or more of your trvs are not bidirectional and are on the wrong side of radiator(s).
  12. F

    Vaillant Boiler - problem with boiler

    first thing to get sorted is the gas pipe supplying the boiler.once thats done you can then see what the performance is.
  13. F

    glow worm gp40

    give me a ring and ill call and quote you.
  14. F

    worcester 9.24

    check plugs on pcb
  15. F

    glow worm gp40

    switching would save you money , but you will only gain once the cost of the swap has been recouped in gas savings.possibly 10 to 15 years
  16. F

    I like it warm, but not this warm!!!

    turn it down or off
  17. F

    heating wont come on on its own

    loads of lagging around the tank should help.
  18. F

    Separate heat sources for HW and CH?

    the 13ltr for the shower is a mix of hot and cold , so you dont need 13ltr of hotwater.i would contemplate something like a 33kw.im fitting (after a couple of years of others testing and sorting the new boiler syndrome problems out) the baxi 28 , 33 , and 40kw boilers ,i think their performance...
  19. F

    Help! Boiler replacement in Stafford area.....

    boiler , trvs +lockshields , wireless stat etc 2500 quid .( vaillant or baxi)
  20. F

    Hi All, warning code LF on ideal icos boiler

    went to same boiler yesterday where condense pipe went into 3in downspout which had frozen at the bottom. as the snow in the gutter melted , it filled the pipe and back up the condense and filled the boiler.water flooding out of boiler , water in gas valve.LF code showing.i would check your...