Search results

  1. F

    baxi 133 he plus

    dry fire fault code showing. boiler is full of water , theres no blockage and flow switch shows continuity when pump runs. any ideas.
  2. F

    Would you believe it?

    its always better to get the boiler as close to the outlet as possible. could have been mounted six inch lower. :lol:
  3. F

    where to purchase from????????

    mrcentralheating
  4. F

    Will a combi give me enough flow?

    worcester 550 cdi = 25l/m = 2000 quid.
  5. F

    ocean alpha 240e

    if not , first call would be cleaning the venturi.
  6. F

    ocean alpha 240e

    has there been any electrical work done on the premises preceeding this fault.
  7. F

    halstead

    moving production to stoves in whiston, liverpool. closing all but one warehouses down south.i wonder whether they can improve boiler and sales.
  8. F

    halstead

    halstead are being bought by the company who have valour , dimplex etc etc
  9. F

    New system, how's it looking?

    how much was the cost
  10. F

    g/w compact 100e

    pressure at 1.3 br, hot water working , heating working yet low pressure light is flashing. any ideas.
  11. F

    vokera

    whats vokera boilers like for fitting , working on and reliability.
  12. F

    Ferroli Optimax Reset.

    hope its usefull to everyone.
  13. F

    Ferroli Optimax Reset.

    Ferroli Optimax f12 code= pcb confused. To reprogram you press reset for ten seconds and TS appears. Press reset for one second and P01 appears. Press heating + and p02 appears. Press hot water + and 0 codes appear. Then press up or down on heating + or - to get o1 . Then press reset...
  14. F

    ferroli optimax

    customer said his heating wasnt on but his hot water was working then he pushed some buttons on the front and now f12 wont go off no matter what you try.
  15. F

    ferroli optimax

    does anyone know what f12 fault code is. its not in the manual.
  16. F

    Worcester Combi 24i Boiler

    i would guess a faulty earth or neutral.
  17. F

    Need Help with Mid posn plus two port valve Unvented System.

    check that there is a permanent live from the clock to the wireing center.
  18. F

    new regs

    so it finally comes out , your a window cleaner.
  19. F

    new regs

    i think a quote from animal farm is appropriate here."everyone is equal,but some are more equal than others"
  20. F

    Unusual hot water problem-one for debate!

    i had similar problem and it was the min burner pressure set to 6mbr instead of 2 mbr.
Back