  1. J

    A Real Jaw-To-The-Floor Moment...

    Have you seen the guy's ID card? What is the membership number? If you search for the company's name on the NAPIT site, it will prove that company is a NAPIT member. Personally I find this difficult to believe unless the individual is not registered for full scope, he may be working outside...
  2. J

    can i get away with this.

    That would be 2kW to the 17th edition! Regards
  3. J

    Wiring & buildings regs - how do they know?

    Horse tied up at the front door, spurs on your safety boots, quivering bottom lip, sweating, licking of lips, not eyeballing, blinking rapidly and length of nose are all giveaways. Or how else would your spouse recognise you were telling porkies? Regards
  4. J

    High integrity earthing and ring final circuits.

    The CPC's are shown using two ways of the earthing terminal block inside the CU. How does this relate to the sequence numbering allocation for the MCB ways? Regards
  5. J

    earthing outbuilding

    I assume that you're using SWA, use the armour as the CPC as a minimum. Your other options: - Provide a 3rd core for another parallel CPC. Install an earth rod or rods, they can be driven at an angle to avoid rock, if feasible. It would all depend on your existing Ze value - the loop...
  6. J

    My disagreement with LABC re testing of electrical work...

    Complain here: - http://www.lgo.org.uk/complain.htm Regards
  7. J

    My disagreement with LABC re testing of electrical work...

    This is an extract from the following site:- http://www.communities.gov.uk/planningandbuilding/buildingregulations/circularscircular/divisionalcircularletters/buildingregulationspart/ Where, however, notifiable electrical installation work is to be carried out by a person not registered...
  8. J

    Front indicator lamp/lens colour?, mine are clear.

    A condition report on the invoice, after a repair to the engine by the mechanic - front indicators are "white", I think he means that they are clear, which they both are. Should they be coloured amber as the rear ones? - N registration 1996 model. if so, I have the choice of the cheaper...
  9. J

    Stop/Reset switch for pump question........

    The stop button should be the very first item in series in the control circuit, for safety reasons. Regards
  10. J

    installing a wireless energy monitor

    The site gives instructions: - http://www.theowl.com/in-the-home.php
  11. J

    Renault Kangoo Immobiliser - How to defeat?

    I bought a Kangoo 2nd hand, there was only one key supplied, this was the master key which covered the central locking and the immobiliser. The pushbutton switch has broken from the printed circuit card, I am struggling to resolder this since I can't see the position where it has broken from...
  12. J

    Demand in Scotland for Electrical Testing

    Inspection and testing is not just applicable to part P. "my Inspection & testing Cert BS7671" Is this C&G 2391? If you are considering carrying out Periodic Inspection Reports - this requires a lot of experience on installations as well as having C&G 2391. £2M Professional Indemnity...
  13. J

    Part P dilemma

    If you have studied BS7671 and preferably passed the 2381 exam recently, then consider yourself able to carry out domestic work. Regards
  14. J

    New lights- tripping mcb

    It may be the initial current surge which is causing the trip. I would try a 6A type C MCB, assuming that your existing one is a type B, this has a "slower" trip curve and is commonly used for such situations. This should be done only after a competent electrician has investigated the...
  15. J

    interesting job which i need advice on.

    Halfords sell a trickle charger which plugs into the cigarette lighter socket. Regards
  16. J

    motor question

    There should be a nameplate on it, what are the details. If there are only three wires, are you sure this is a 3 phase motor? If it is, then it's star connected, since the star ends of the windings are inside the motor i.e. not at the terminal block, this would be unusual - all the winding ends...
  17. J

    fitting a shower

    Rubbish, I hope you don't call yourself an electriciandesigned From Jan 1st until 30 June 2008. Installations can be designed and installed, using either the 16th or the 17th. If however, an installation that has been designed to the 16th edition between Jan 1st and June 30th; but is not...
  18. J

    Part P and Consumer

    I always use a neon screwdriver for pinching! - belt and braces; and bits of string! Locking devices: - http://www.thefusecompany.com/advanced_search_result.php?keywords=lock+mcb&sid=e63d58566e84d5efcf21821587bf3d95&x=7&y=14 http://www.reecesafety.co.uk/Downloads.htm...
  19. J

    SECURITY LIGHTS IN BACK GARDEN FRONT ENTRANCE NOT WORKING

    Why didn't you get him back to sort it out; or doesn't he answer his mobile? Did he give you a certificate for the work? this is required to the regulations. Jaymack
  20. J

    Wireless Alarm - How long to install and commission?

    I am getting telephone calls, to give a quote to fit the customer's purchase of a wireless alarm system. As an example 5 rooms with PIR's, a bellbox, a keypad and 2 door switches. Are they programmed similar to the wired versions; are they easier/more difficult? I would estimate a...