    HOW TO I CONTACT ADMIN

    I am a RGI and have been told about the combustion chamber forum. How do i contact someone in admin to learn more. Regards Neil
  2. N

    POTTERTON ENVOY F CODE / NOT IGINITING THOUGHTS PLEASE

    What do you mean "these are sods?" Do you mean the Envoy? I have a few BG friends who i did my training with they also said these are a nightmare.
  3. N

    POTTERTON ENVOY F CODE / NOT IGINITING THOUGHTS PLEASE

    I wasnt aware of the combustion chamber forum is it part of this forum or another site? I am going to check 2moro although during the service everything seemed ok. (ignition ok etc..) I really just needed some starting points so thanks again.
  4. N

    POTTERTON ENVOY F CODE / NOT IGINITING THOUGHTS PLEASE

    I am corgi registered so fitting is no problem, would this fault be intermitent if the igniter was dead? Is there a possibilty the igniter could be on its last legs or is this unlikely
  5. N

    DAMAGE FELT HOW BEST TO PATCH IT

    I have recently put a boiler flue through a roof and have damaged some of the felt. I need to repair it and keep the customer happy however replacing all the felt is not an option. I have been advised by other plumbers that i should use felt nails to hold the torn felt back up and tape it, or...
  6. N

    POTTERTON ENVOY F CODE / NOT IGINITING THOUGHTS PLEASE

    I serviced a friends Potterton Envoy about a month ago and he is now reporting that it keeps locking out "F" code. Im due to go back to take a look but could do with a few opinions as im new to Gas work. (First year) The main suggestion i have had so far is check that the igniter is not...
  7. N

    MAKING A PADSTONE HELP

    Does anyone know the correct mix for making my own padstone. Its going to be 300 deep x 100mm wide and 600mm long. I cant find a lintel deep enough to cut down and the place concrete place i was going to use is taking too long (the props are on hire and its costing me) Its RC30 but i dont know...
  8. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    He was repeatedly asked to state the working pressure at the boiler. He kept on quoting a standing pressure of 30 mB. I assume that he is some kind of gas trainee. In this case his tutors have seriously failed to teach him the relationship of the key gas pressures to be measured! Your...
  9. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    RANG TRANSCO...... THE MAN ARRIVED...... THE REGULATOR WAS REPLACED..... AND WE NOW HAVE BOILING HOT WATER...... :D SO... A BIG BIG THANKS TO ALL WHO POSTED!! (AND AS A BONUS THE SHOP EVEN LET ME RETURN THE PCB I BOUGHT... RESULT!!)
  10. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    Well done to all those peeps who said Transco.... :D I will b back with results soon....... :?: :?:
  11. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    checked working pressure @ boiler and meter and its 2.5 at meter and 2.0 at appliance. therefore i guess i should ring transco! Any one agree with this... it could be the one!!
  12. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    Working pressure is measuring 2.5mb
  13. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    I tried a new PCB and it hasnt made any difference, can anyone explain why the burner pressure isnt changing when i adjust the 2 nuts to the front of the gas valve?
  14. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    The black D shaper plastic does have 401 printed on it. voltage of mod coil is 15v Max Im not sure how to check the resistance of the mod coils im afraid. I have just tried a brand new PCB which has made no difference at all so guess thats out the equation. What have you got in mind?
  15. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    done some checks and these are the results MODUREG TESTS CH On Max Temp = 10.54v DC CH On Min Temp = 1.47v DC HW On Max = 10.69v DC HW On Min = 10.8v DC (although crept up from 4 slowly) GAS VALVE TESTS (HOT TAP ON FULL) 9 L/P/M The standing incoming pressure 30mb BURNER PRESSURE MAX...
  16. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    i will re check again today, when i checked yesterday working pressure was about 30mb (top of the gauge) The burner pressure was about 2mb (although the burner appears to be on full this however may not be the case) I couldnt get the boiler to fire with one of the black leads off, should i...
  17. N

    waste pipe diameter

    best bet is to cut out a section of the pipe and get the correct fittings while you are in the store. will save you messing on with incorrect fittings. I still see plenty of waste pipe bigger than 40mm attached to macerators so it could still be a metric size rather than old imperial.
  18. N

    Repairing a damaged Radiator bleeder

    I may be miss interpreting this but dont these bleed valves have a larger nut holding them into the rad? If u get some grips on it you can bleed from there and also get a replacement.
  19. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    No the water isnt going down the flow pipe thats for definate! All the boilers i have worked on so far have actually been Vaillants... to be honest i to have not seen that type of diverter in anyother Combi but as my experience is limited i wasnt sure if they were more out there. Cheers
  20. N

    Hot Water Not Getting Hot baxi 105e.. The Return!!

    Right folk, I have been in touch with Baxi regarding this issue and heres whats been said, Main issue is where is the heat going? If its not going down the flow then it must be going somewhere or the boiler would cut out in minutes! I have checked the pressure to the gas valve which is...