  1. J

    Vokera Boiler/Central Heating

    try bleeding the pump first then. Does HW work ok all of the time ?
  2. J

    Vokera Boiler/Central Heating

    does HW work ok all of the time - boiler fires up and stays on ok? I'd check pump first
  3. J

    Potterton Kingfisher MF H/W Problem!

    do you have gravity fed hot water or a fully pumped system? what's the boiler stat set to?
  4. J

    Central Heating boiling over into header tank

    do you mean overflow pipe outside or vent pipe over the header tank?
  5. J

    Central Heating boiling over into header tank

    if no room stat onj your second zone it will be controlled by the boiler stat (if older tpy ewill cycle on / off boiler stat) - when you say boils over, do you mean like steaming and then you hear a gush of water going down the cold feed to replace the lost system water? if so sounds like...
  6. J

    Pump/Fan Overrun question

    mine has a fan overrun but no overrun stat!!
  7. J

    Pump/Fan Overrun question

    worcester junior 28i - but was just enquiring in general too
  8. J

    Pump/Fan Overrun question

    Hi Most, if not all boilers nowadays have a pump or fan overrun built in to remove the residual heat after a demand has ended - but mine has no pump or fan overrun stat, so wondered how it work/was controlled? Is it done by the board? ....
  9. J

    Overflow Leaking

    you def have a combi boiler? no hot water cylinder? other things could be plate heat exchanger pinholed and causing mains water to force primary water up through tank and out of overflow....
  10. J

    Overflow Leaking

    so you put in an open vented combi boiler? what's the water level in the hedaer tank when system is cold?
  11. J

    Hot water cylinder venting for first time in years- why?

    How much water is coming out of the vent-pipe? Is it a drip or a half decent flow?
  12. J

    Old boiler - worth getting new one?

    My boiler's approx 20 years old Glow worm Fuelsaver UFB), the gas valve has failed on it recently - the boiler's not too great, a bit rusty, damp, water inside. Is it better for me to hae a new boiler installed, and if so, can anyone recommend me a decent one? I have an open vented system...
  13. J

    Bristan cold shower

    any isolation valves fitted which are not fully open? or a chechk valve? or a filter/cartridge partially blocked??
  14. J

    Glow worm 30cxi pressure problem

    sounds like an expansion vessel problem. Have you checked the air charge in it?
  15. J

    Glow worm Fuelsaver problem

    The pilot goes out when boiler's stone cold/immediately - following the boiler manual it doesn't mention the pump overrun/stat at all
  16. J

    Glow worm Fuelsaver problem

    A quick query/problerm with my old Glow worm. Basically the pilot goes out when releasing the gas button. It held for a few hours late last week, and for about a minute yesterday, but now no joy at all. I've tested the thermocouple, cleaned the tip, checked it's voltage and it is good. I...
  17. J

    Thermocouple for Glowworm Fuelsaver 50

    Hi Is it possible to get a thermcouple for a Glowworm Fuelsaver 50B boiler any more? Trouble is, as it has an overheat interrupter, I'm sure a universal t/c won't work....
  18. J

    mr combi dvd *****

    Hi I have the fault finding DVD set - it's OK, teaches you how to test parts using a multi meter - the second disc gives you notes which add a bit more info - it's not bad for learnign some basics. But you need to get hold of an old combi and test parts yourself to learn better in ym opinion
  19. J

    Stopcock leaking

    you'd be better off fitting a new stopcock after the old one as suggested (if space allows) - on the copper pipe
  20. J

    RE: BOILER PRESSURE PROBLEM - PLEASE HELP!!!

    I guess, must be rare to have less than 1.5 bar mains pressure