    Kitchen Extractor ducting

    Hi, I want to replace the kitchen extractor ducting as it was installed by the previous owners of the house and is held together with tape, and looks a mess. Its also not all that effective as the air escapes the joints. The problem I have is that the extractor appears to have a 4.5 inch...
  2. S

    Replacing fused spur

    Sorry when I was referring to the solution above I meant with the GRID 20Amp switches ( as proposed by JohnW2 ) and the fused spurs on top of the units. I did not mean the fuse solution which I agree could be problematic.
  3. S

    Replacing fused spur

    The backbox is 25mm but there is small cavity around the box that I could put the inline fuses. The solution above seems my best option. Thanks to all of you for your help. Kind Regards Steve
  4. S

    Replacing fused spur

    Hi, sorry I wasnt clear in the original post. There is a WIFI LED controller between the power supply and the strip lights which allows you to turn them off. Thanks Steve
  5. S

    Replacing fused spur

    Hi, one of the cables is already through and is 2.5mm t+e. I can get another cable through should I be able to add a double switch as discussed. Thanks Steve
  6. S

    Replacing fused spur

    Hi thanks for that. The only reason that I want two individual switches is that the power supply for the strip lighting is 100w and it means everytime we want only the under cabinet lighting on, the transformer will be powered up but not powering anything. Regarding the switched left on and...
  7. S

    Replacing fused spur

    Hi, I was hoping to get away with a 1g box as the wall is tiled. What I was hoping is that I could wire up from the existing socket to a double light switch ( 1 gang ) that would replace the existing fused spur. I would then have a wire from each of the switches up to above the cabinets where...
  8. S

    Replacing fused spur

    Yes sorry it comes from a double socket that is sits next to the existing fused spur that Im wanting to change. If I ran from the switches ( that would replace the fused spur ) and put fused spurs before going to any lighting transformers would this not achieve the same?. The only reason I was...
  9. S

    Replacing fused spur

    Hi, the fused spur was originally put there to support old style hallogen lighing in the cabinet. From the fused spur the wire runs up to the top of the units and into a junction box to the various lights. I am removing the old lights so the only thing that will be driven from the switches...
  10. S

    Replacing fused spur

    hi, I am in the process of installing some lighting in a utility room. I am going to use led strip lights above and at the bottom of the units and some triangle shaped bench lights above the unit benches. Ideally I want the bench units and the strip lights switched independantly, however...
  11. S

    Strip LED lighting in kitchen

    Hi, Im looking at putting some RGB strip lighting into the kitchen units. I would ideally like the same lighting colour to be at the top and bottom of the cabinets and use a single power supply ( that is capable of running the configuration ). Would the configuration in the diagram work...
  12. Strip LED

    Strip LED

  13. strip led

    strip led

  14. S

    Radiator humming

    Hi mate, Yea, it has 0, followed by the snowflake symbol, then followed by a 1 etc. So from what you have described the TRV is broken. Thanks again for all your help. Steve
  15. S

    Radiator humming

    Hi mate, The TRV is on 0 as you mention when it happens. However, the radiator still heats up first thing in the morning as the bathroom can get quite chilly through the night. Thanks for you help. Steve
  16. S

    Radiator humming

    Hi, thanks for your reply. I havent tried turning it right up as turning it up a little bit appears to resolve the issue. I will try turning it right up next time it occurrs. Are the valves easy to replace? Cheers
  17. S

    Radiator humming

    Hi, I am having an intermittent issue with the bathroom radiator that is occasionally creating a humming ( vibrating ) noise. The radiator is turned off at the TVR, however it comes on occasionally when the bathroom gets really cold ( when I first turn the heating on in the morning )...
  18. S

    Recessed Lighting drafts

    Hi mate, yeh the downlights have a seal that swells in the event of significant heat ( well thats what the electrician told me anyways ). The problem with this is in an everyday scenario this doesnt seal to the plasterboard. Can you get ones that do ( have a rubber seal etc ) that are also...
  19. S

    Recessed Lighting drafts

    Yea mate, but to be honest Ive researched and couldnt find an answer so pretty much expected that would be the best solution. Im amazed there isnt a solution out there to be honest though. Lighting a sloping ceiling isnt the easiest of things and recessed lighting just sounded like the best...
  20. S

    Recessed Lighting drafts

    Hi, I got an extension completed last year which included a small computer room which used 6 firerated adjustable LED recessed lights for lighting. The room has a sloping ceiling. I have noticed that when it is very windy there is a very slight draft. I imagine this will be caused by the...