    Cracked Paint

    Hi, My bathroom paint has cracked as shown in the photos :cry: . Any ideas why? Any advice on the best way to prep surface for re painting? Walls are painted plasterboard Thanks
  2. T

    Arctic Flex

    Hi, From what I have been reading on the forum, I need to upgrade the wiring for my 3 x 150 w security lights which are fed from the garage lighting circuit. I plan to use 3 x Ashley J501 16 Amp Downlighter Junction Boxes inside garage fed by 1.5mm t&e, with 1.5mm arctic flex between each...
  3. T

    Washing Machine & Tumble Drier in Same socket

    I thought it worth posting the set up I have in my utility room to highlight the dangers of putting a w/m & t/d in the same double 13amp socket, and not taking professional advice from an electrician. I used to have just the w/m in the utility but got a plumber to alter it so the drier could...
  4. Gride switch rear 2

    Gride switch rear 2

  5. Grid switch rear

    Grid switch rear

  6. Grid Switch

    Grid Switch

  7. T

    current capacity of spur socket

    No fuses - just dp switches What I'm not sure about is whether the double socket might be overloaded - rectified by the singles - or the supply cable overloaded. Or just the fact that you cant have 2 singles on a non fused spur?
  8. T

    current capacity of spur socket

    Out of interest, I have seen a washing machine and tumble drier plugged into a double socket, contolled above the worktop from a tenby grid switch. Would it be acceprtable to change the double socket to 2 singles in a dual box, with one switch receiving a supply from the isolator, then...
  9. T

    Swa earthing/termination

    None of these so sounds like I should be ok. Thanks for all the info.
  10. T

    Swa earthing/termination

    TN-C-S. Please say if this changes things. Want to get this right, even if it means paying the pros to do it for me. Thanks again
  11. T

    Swa earthing/termination

    Thanks for your speedy replies. Sounds quite tricky. At the shed, I have done the same - just cut the armour a bit short then run the 3 core and sheath into a 6 cm bit of plastic conduit to the fcu. Other posts have mentioned earthing at supply end but it would be easier for me to wire...
  12. T

    Swa earthing/termination

    I have my shed connected to house by3 x 2.5 mm swa in to a 13amp fcu in house which is rcd protected at the cu. This terminates in shed to another 13 amp fcu which supplies a twin socket, and then a 3 amp fused connection unit for light ( all latter switches and boxes metal). My only...
  13. T

    Consumer Unit Safety

    Thanks for all that. For clarification. I could turn off the main switch and work with care in the consumer unit once I have checked all is dead? I assume that the CU main switch should isolate the neutral too? When you say the meter is single pole, what does that mean - does it mean when...
  14. T

    Consumer Unit Safety

    I have an MK consumer unit. If I switch off the main switch, I am ok to rewire my garage lighting circuit, which feeds from the consumer unit from a dedicated mcb? i.e to work safely in the mcb with the lives and neutrals OR Should/can I switch the supply off at the meter, which has a...
  15. Meter

    Meter

  16. Consumer Unit

    Consumer Unit

  17. T

    Attic Lights

    Thanks again - appreciate the advice.
  18. T

    Attic Lights

    Upgrading lights in attic. Existing lights consist of 1 flourescent tube and 1 pendant, with the switched lives twisted together in L1. Should 1 of these go in L2, or does it not matter? Or does L2 do something different from L1? Lights at other ends of attic so thats why there are 2...
  19. T

    Security Lights

    Hi, I want to put a couple of security lights up on side of my house. I have worked out how to continue my upstairs lighting circuit to supply the lights. 2 questions: If I do this, can I wire these lights together ie wire light 1 to the isolator switch, then wire light 2 to light 1? I am...
  20. T

    Ring Main Regulations

    Thanks again. I think it sounds too challenging for me.....appreciate all your input. I will need to get a professional in to take a look.