  1. J

    small wind turbine home built

    Sounds like a good project, I plan to build a water wheel generator as I have a stream in my garden! But I am also looking into becoming a registered installer of renewable energy systems,although costly there is a big advantage, if it is correctly certificated you get paid for all the energy...
  2. J

    Electrician, Career Chang Advice

    I've had two guys work for me who had done the qualify quick route both where useless as they had minimal practical experiance and neither had what I would consider a competent level of technical knowledge. I wouldn't employ another or use any tradesman who has not done a proper apprenticeship...
  3. J

    correct sixe swa cable?

    if you think 35mm is expensive you should buy a few hundred meters of 240mm or larger :shock: at a guess i would say 6mm might be ok but possibly not, thats why you should pay someone to design it, rather than ask for it for free
  4. J

    11kv Circuit Breaker

    i've seen a HV breaker after its kicked off in a simular fashion, that was in a mine and it was caused by the gear getting damp after some donut turned the heating off :roll: you can see why the boys who operate them often use a remote switching device :? bit i like most is when u rack...
  5. J

    My Drill!

    i dropped on of my dewalt drills off the top of a bridgewater carnival float a couple of years ago - a good 20ft drop its still going stong today....
  6. J

    Electrical contractors in industry

    i looked at a job yesterday which i had priced 3 years ago but lost due to being a few grand too expensive (price was over 400K so there was nothing in it) job which the contract winner had done was appalling at every point i looked at it and there was alot of work which had not been...
  7. J

    Catastrophic Failure Of LV-SELV Toroidal Transformer

    big black mark on the ceiling, always a good indication of the fault!
  8. J

    dual rcd?

    Just to add to the arguement i think RCD protection for domestic lighting circuits is mad, as quoted earlier and by others old person alone in the dark is a bad situation.. At the end of the day domestic wiring should be inspected and tested 5 yearly to reduce the of fire etc and our...
  9. J

    20mm holesaw Vs 20mm punch

    It should be a piece of cake to drill a 20mm hole in a bit of thin metal like a piece of uni strut i regularly use hole cutters for holes up to 80mm in steel often 6mm thick stainless is a pain ally is also a pain but a bit of wd40 makes a massive difference! you should easily be...
  10. J

    Air to air heat pumps

    Im looking at installing a air con unit in my house, not for cooling but for heating. I'm told that with modern inverter driven air con in heating mod you get a very effiencent heating device ie around 1kw in and 3+ kw out. Has anyone else done this at home
  11. J

    17th edition

    the exam is easy if you have a grasp of the book and know how to read C+G questions
  12. J

    For the sparks who think 2 way lighting is complex

    That's a lot of I/O then! This one has a few remote I/O stations too. It's only on a batching plant so it isn't massively complex it's just a mess just out of intrest what industry do you work in
  13. J

    For the sparks who think 2 way lighting is complex

    the plant control has been extensively modified so additional I/O was required, theres another rack in the same state in the next panel, i priced to replace the enclosure etc when the I/O had to be increased. but didnt get the job!
  14. J

    For the sparks who think 2 way lighting is complex

    it is horrible when the place breaks down you cause more faults trying to fix one..... i do delight in ringing the man responsible for must of the carnage(at odd times of day) and asking for the diagrams... his responce, its hardly modified the drawing are current :?
  15. J

    For the sparks who think 2 way lighting is complex

    welcome to my world, and we all love pictures This is a PLC which has suffered from continous modifications (not by me) i used to be able to fit the trunking lids a few years ago! under the spagetti there are relays terminals etc etc and the drawings are not accurate anymore...
  16. Untitled

    Untitled

  17. jeepmadmike

    jeepmadmike

    mikes pics
  18. J

    become a sparky

    It's not just qualifications it the hand skills and experiance to do the job!
  19. J

    Who offers a 24hr callout??

    We offer a 24/7 service, but it is extremely rare to get new custom from it, but a lot of our existing customers have plant which works odd shifts etc I cover Devon / Cornwall and somerset and usually have only one call a month for night time breakdowns compaired with a couple a day during...
  20. J

    Picture of the week!™

    From what I can see in the pic on my phone, 1-the supply appears to be from a bus bar chamber above the DB and there is no sign of any protection. 2-the DB is not IP2X due to the missing cover. 3-cables from old version of BS not sleaved or identified. 4-earthing is a bit lacking but the...