Search results

  1. W

    Recommendations for a new super duppa Boiler please!

    It is now against partl to fit a rad in a conservatory
  2. W

    vokera 24 hw problem

    If i remember right on a compact it is on the hot water pipe outlet on rhs of heat ex under black grommet. Don't worry if old one is blue & new one is red
  3. W

    Powermax 155x - newbie question?

    try downloading manual from range powermax website (baxi) but timer may be faulty
  4. W

    vokera 24 hw problem

    Change dhw thermister & while you're at it take out flow restrictor as it will soon reduce water flow
  5. W

    Overheat that won't clear - Baxi Solo3 with 2 heat 1 water

    You probably have a problem with air hence no circulation causing overheat. It should reset when boiler cools down again but if there is no water movement it will overheat again. Are there any bleed caps anywhere to release the air & have you bled the pump
  6. W

    Condensation in crawl space

    post on a building forum not plumbing
  7. W

    Glow Worm economy plus boiler

    What kind of system is it? on a y plan you should be able to have htg only but if you have a 2 port valve on htg side (c plan i think) then you will have no control over water when htg is on
  8. W

    Recommend me a boiler ?

    Vaillant or worcester but probably not for that price unless short cuts are taken
  9. W

    Very confused... please help.

    Mira event is a pretty good power shower (cabinet type)
  10. W

    Potterton prima F

    When you state no hot water out of tap is it cold or no water coming out at all? Assuming the former you will be running the c/htg system without any water in it so make sure small tank in loft is full,& try to remove air (there may be a bleed cap on the flow pipe to cylinder)
  11. W

    Vaillant TurboMax HW problem...Help!!!

    When hot tap is running feel the 22mm pipes under boiler if they get hot you need a new diverter valve
  12. W

    Ideal Response 120 - Burner problem

    The flue overheat stat must be fitted in case the flue baffle has deteriorated causing excessively high flue gases
  13. W

    help old 'ideal' boiler British gas service has condemed it

    No clarification that boiler is positive fan flue as i mentioned earlier. If it is then NO attempt of a repair should be made using incorrect seal
  14. W

    Ravenheat RSF84ET DHW temperature stability

    Budget boiler should have got a better one
  15. W

    help old 'ideal' boiler British gas service has condemed it

    If your case seal has gone your boiler will be dangerous especially if as i believe it is a positive fanned flue which is probably why he gave you a co detector rather than risk going to court accused of corporate manslaughter
  16. W

    heating pipes in wall

    Why not replace pipes with barrier plastic
  17. W

    Vokera Linea 28 help

    If you lose pressure in a few days & the blow off is dripping then all that is needed is a safety blow off valve (easy enough to fit)
  18. W

    Hot Water & Central Heating

    How do you know pressure is 1.5 bar unless you have dropped 2 screws & lowered electric box? Have you got any external controls ie is black link still connected or do you have a room stat etc
  19. W

    Correct Bayonet fitting for hob

    You cannot fit a hob on a flex in other words you must get a r.g.i. to fit hob with rigid or semi rigid connection
  20. W

    Heating is contantly on - thermostat broken?

    The ideal classic is NOT a combi boiler what control plan do you have ie y plan s plan etc as valve may be defective
Back
Top