  1. J

    Hob/Oven wiring

    Thanks as the oven is coming tomorrow I have just replaced the 13 amp FCU for a CCU and bought the 2.5 heat resistant flex and will use that.Like the idea of the double CCU but couldent find one local.thanks for your help
  2. J

    Hob/Oven wiring

    Right sorry if I confused you .I have exactly as you say here [/URL] The 13 amp connection unit was where the old oven was connected.Could I just replace that with a 20 amp flex outlet plate for the oven[/img]
  3. J

    Hob/Oven wiring

    Ok so just wire the oven in to the 45amp connection unit along with the hob .I will remove the 13 amp fused connection unit completely.So no fusing down is required then for the oven then
  4. J

    Hob/Oven wiring

    Just removed my old fan oven and this has been connected via a 13 amp connection unit spurred off the hob supply.Now as the new oven needs 16amp whats the proper way to connect this do I just use 6mm cable spured unfused or can I get a dedicated 16amp oven connection unit.Any help please
  5. J

    Hob/Oven wiring

    I Am about to replace my single oven with a bosch which is rated at 16amp (3.5kw).At present the old oven and hob is on a 32 amp breaker connected via a 6mm cable with 2 separate connection units.Is it Ok to connect the oven 3.5KW and hob which has a total rating Of 6.5kw on the same 32amp...
  6. J

    Entry /Exit zone

    Area A is ticked .Do I just make zone2 Entry/exit1.It is not the time factor that sets the alarm off but when I walk past zone 3 or 4 PIR.Thanks for the advise will try this tommorow
  7. J

    Entry /Exit zone

    Entry 2 delay time is set at 45secs
  8. J

    Entry /Exit zone

    premier 24
  9. J

    Entry /Exit zone

    Back door is zone2 which is set as entry/exit2 as default .If I have set the right part in areas settings I have exit delay time set at 20 secs,Entry1 delay time 30secs,Entry2 delay time 45secs and second entry time 30secs
  10. J

    Entry /Exit zone

    Have set up my texecom with 2 entry/exit zones. 1 is front door which I have 2 pirs set on guard access as they can just see you when arming/disarming which works ok.Problem I have is when I arm the system and then enter via back door (entry exit zone 2 ) the alarm goes off when the same 2...
  11. J

    Part Arming Texecom elite

    Hi is there a way to set a part arm to internal siren only at night only thanks
  12. J

    Zone Setup

    Sorted
  13. J

    Zone Setup

    Only have 1 keypad at present so will split in to 3 parts then Thanks
  14. J

    Zone Setup

    Have now got to the stage of programing my texecom Premier24 and after some tips as the best way to set it up with wintex.I want to be able to arm downstairs at night the complete house when out and also the workshop at night and when out.Is it best to set them all as 1 area ie A and into 3...
  15. J

    USB Coms lead

    Have finished the wiring of my texecom panel thanks to some help on here.Now just had a look at the programing whick looks very complicated using the keypad. Is http://www.ebay.co.uk/itm/Texecom-Premier-Elite-USB-Com-/281170153664?pt=UK_Burglar_Alarms&hash=item41770c10c0 lead correct as I may...
  16. J

    Door Contact Readings

    Back again wiring last door contacts ,hopefully some one can confirm this is right. I am wiring 2 door contacts for double doors on 1 zone have wired them I think in series with a 4.7k resistor over each switch .Readings Im getting is both doors open about 11.6k,either door open 6.8k and both...
  17. J

    Door Contact Readings

    Hi Im in the process of installing a texecom system with no previous experience of them and trying to do some testing as I go .Installed all the pir's with EOL wiring which I think are OK. Now at the stage of doing the door contacts.What I have done is bridge the reed switch contacts with a...