  1. M

    Plumbing / gas engineer national rates of pay

    that i dont disagree with but our company pay directly inline with the rates shown, we have a lot of GAS qualified plumbers which they tend to favour even though most of ours couldnt tell you how a boiler works !! the only issue we have is they are saying this is a plumbing rate ONLY...
  2. M

    Vokera linea 28 domestic hot water problem

    came across 3 recently , same problem PLATE HEAT EXCHANGER.. how easy are these to clean guys ???
  3. M

    Help needed!! General gas boiler question (hissing noises)

    pretty hard to give any real advise mate, too hard to tell, but the pressure guage should sit just above 1 to 1.5 when hot, if the pressure is rising it could be a few things but hers 2 to consider.. 1. Faulty or no pressure in expansion vessel. 2. blockage in the system causing pressure to...
  4. M

    Plumbing / gas engineer national rates of pay

    Guys, having a little dispute at work over wages etc . work for a large maintenance company just now and normally our wage rises etc are set with Scotland and Northern Ireland (SNIJIB) suggested rates of pay. Now our bosses are stating these rates are only applicable to PLUMBERS and not GAS...
  5. M

    Help needed!! General gas boiler question (hissing noises)

    do not listen to your non corgi reg mate for starters.......... thats seriously bad advise he has given you........ your gas pressure is regulated at the gas meter then the gas valve... If your boiler is sending too much gas through then the gas valve would need the correct burner...
  6. M

    vokera mynute 20e

    sound like the pump my friend , does the boiler kettle up then go to lockout ?? first place i'd start if the thermister has been cheanged
  7. M

    BEST COST EFFICIENT WAY TO HEAT STORED WATER ?

    guys I do work for a local housing, not my tenants !! just looking for the cost efficient answer which does appear to be 2 x cycles etc !!! cheers
  8. M

    BEST COST EFFICIENT WAY TO HEAT STORED WATER ?

    Never advise the immersor myself but always get asked if keeping a constant heat is more efficient than heating from cold... could never really answer but always advise the am/pm cycles !!
  9. M

    BEST COST EFFICIENT WAY TO HEAT STORED WATER ?

    Keep getting asked this by tenants and have no real answer so wondering what you guys think OR KNOW ?? Ok gas heating stored water, normal family use whats the most cost efficient way 1. H/W ON CONSTANT stat set to 55-60 2.H/W ON AT SET TIMES OR BOOSTED AS REQ 3.H/W ON CONSTANT +...
  10. M

    potterton Lynx Electronic

    no need to panic... ps. have a look and see where its leaking MAY NOT require a washer, a nip up with a pair of grips often cure thee leaks !
  11. M

    potterton Lynx Electronic

    basically when its running hot the metals expand therefore no leaks, when it coo.ls it has more chance of leaking.. lynx electronics are very old so normally perished washers etc cause this, most are cureable with a nip up of the compression joints and at worse replacing seals !
  12. M

    NO HEATING DOWNSTAIRS !!

    job done !!! pump appeared ok,valve body nice and fee.... removed valve head and it didnt fire up boiler or power over when c/h only called for... can only assume partially opening and small enough resistance to only heat upstairs... strange as the pump was deffo my first choice here...
  13. M

    NO HEATING DOWNSTAIRS !!

    sorry mate nothing has changed, other than it not now working .. will let you all know how I got on later !!
  14. M

    NO HEATING DOWNSTAIRS !!

    guys heres a bit I forgot to add although may not make much of a difference.. the system has a bypass on it (I know not required on a Y plan ) I was thinking that if the valve failed on c/h then if the bypass is open then this would allow heat to go to the rads but then that had me...
  15. M

    NO HEATING DOWNSTAIRS !!

    aint the balancing m8.. the place has run perfectly for 4 1/2 years...
  16. M

    NO HEATING DOWNSTAIRS !!

    gonna try that tomorrow mate, didnt have time tonight and pump wasnt in a good situation to try.. the pump is my first bet also but just wondered if the mid position valve could cause this also , not done a lot of these but symptons have always been no c/h at all when these need replaced....
  17. M

    NO HEATING DOWNSTAIRS !!

    Quick one guys !! just been to my old neighbours and heating upstairs works when she puts c/h and h/w demand on.... no downstairs heat at all... suprima 30 system with mid position valve ... checked the pump and rocked it form 1-3 a few times,,, checked the valve and thought the head...
  18. M

    How do I open a Potterton Suprima's cover?

    bite the bullet and get a new pcb and A CORGI REGISTERED engineer to fit !! downside is they are about £170 !!
  19. M

    IDEAL ISAR HELP !!

    keep that in mind mate, didnt come back in today so call out guy may have repaired last night... ps. how does this explain the valve head not powering over ?
  20. M

    which circulation pump is best ? opinions please.

    mysons are decent pumps in my opinion and are you disagreeing that the cleanlieness of the system doesnt matter ?? agree grundfoss are best but myson / ideals have always had a good life span when I put them in a clean system... not exacty a pish pump and probably one of the most common used...