Search results

  1. A

    Insulating the internal walls of a loft conversion

    Celotex/Kingspan, that's what i have in mine, as for the flooring area, mine was filled with Rockwool before the floor went done, and then boarded over the top
  2. A

    Yale or Respones wireless alarm??

    OK so is the alarm company NSI or SSAIB?
  3. A

    More darned malware - now is it dying?

    Post the log as an attachment if it will let you, may be easier on the eye.
  4. A

    Yale or Respones wireless alarm??

    I would have thought that under a maintenance agreement you would expect a call out within a reasonable amount of time, seems to me even though the company has given you a quote they don't want the work, if they did i would have thought they would respond, show some enthusiasm towards getting...
  5. A

    Loft Conversion - Removing the support beams

    You may not need planning permission, that's is true in most cases, however the work is still notifiable and inspected by building control, if you do not have the correct permission and paperwork you will never be able to sell it as a bedroom, as your carpenter and builder have stated. If it was...
  6. A

    Dot & Dab depth (say that quickly...)

    Depending on the size weight and type of tiles, it may be better to just S&C and tile straight on top. Only downside is waiting for the render to dry out, but will be the best surface to tile on.
  7. A

    Loft Conversion - Removing the support beams

    There are no images in your albums that i can see, but it does not really matter, get a structural engineer in before you trash your house or do yourself some damage, and if this is to be a habitable space, i assume you have BC involved and the required permissions to do this work?
  8. A

    Wiring a smoke alarm system into a Texecom Premier 48

    Depending on which model smoke alarm it is, it may have a relay output built in, i which case you just wire this to a zone on the panel and programme as 24 hour, or Fire
  9. A

    Texecom ComIP Help needed

    [/url] On the DynDNS website there are Wizards telling you how to configure and test your connection, as for open to more attacks, potentially, but the port number is completely random, most attacks will go for known open ports. If you have MAC address filtering on your Router, you could set...
  10. A

    Texecom ComIP Help needed

    Just type my forum name in the box.
  11. A

    Texecom ComIP Help needed

    Looking at their website the free service should do it, as for straightforward, hey we solved the last one so why not this one, i can send you documents detailing how to load the apps for the online keypad etc onto the ComIP, just PM me your email address.
  12. A

    scantronic 9448 replacing PIR?

    It may not be the PIR at fault, it could be the panel, either way you need to open the box and without the engineers code you will have all the bells going off. I would suggest you contact a local SSAIB or NSI registered company, or a company used by friends relatives to look at it for you...
  13. A

    Premier 24 Alarm System

    The Premier 24 cannot use the ComIP module, this only works on the Premier 48 and upwards. The test message issue is not uncommon, it is not a guaranteed service, are you saying you get no messages at all or are they delayed?
  14. A

    Texecom 48 install....East London

    Yeah big OOPS, but hey at least i am man enough to admit where we were wrong, no point trying to fudge it, just own up, sort the issue, and make sure everyone is happy. At the end of the day all i want is for Tazers alarm to do exactly what he wants.
  15. A

    Texecom 48 install....East London

    By all means give me a call tomorrow, just check the position of the magnet in relation to the reed switch, and the distance the magnet is from the reed switch, should be no more than 20mm MAX. Just want to keep this post updated for the benefit of others who may have similar issues.
  16. A

    Texecom 48 install....East London

    Naughty step done, tech support sorted, time for a beer me thinks :D
  17. A

    Texecom 48 install....East London

    OK so i spoke with Tazer today, thoroughly nice chap. New expander had arrived and still showed the same symptoms, now i have to admit that both myself, and our Tech Support guys had overlooked a couple of things. First, you have to tell Wintex to send/receive Radio Data when you set up...
  18. A

    tiling on floor boards in bathroom

    You could use a 6mm cement backer board, providing there is no deflection in the floor and they are sound. Have a look for posts regarding Marmox, Aquapanel or Hardibacker.
  19. A

    Texecom ComIP Help needed

    You can access via Wintex, or you can use Java apps loaded onto the ComIP, we have an SDK which can be used to load apps onto the module, you can then access these via the device. For example we have an online keypad, you can view the log, you can view the zone status or the area status...
  20. A

    Texecom Veritas 8 Compact - Entry alarm sounding

    Do it right or don't bother, alarm systems are designed in specific ways for reasons, the main considerations are the risk to the property or the contents, the building construction, and the ease of use for the end user, in this case you are the user and the installer, the advice given here is...
Back
Top