Search results

  1. Jamespf1

    Replacing chimney bricks

    Hello, I’ve just installed a new lintel in my fireplace but in the process 2 courses of bricks above the lintel have become loose and I’ve now knocked them out. Can I install the new live of bricks abouce the lintel vertically? Instead of the traditional horizontally laid. Thanks
  2. Jamespf1

    Acro strong boy lintel installation

    Hello, I am installing a lintel for for a fire place but the smallest acros I could hire sit 8 courses Above lintel. Is this okay? Will the brick work hold below it? Will be using strong boys Thanks
  3. Jamespf1

    Subfloor to carpet level

    Hello, what level should my subfloor + tile backboard be compared to subfloor outside of the bathroom? I want to archive a flush run from bathroom to hallway which will be carpeted. The subfloor for carpeted area outside of the bathroom is 25mm floor boards but will be later be built up...
  4. Jamespf1

    Fire place lintel

    Hello, Replacing an old gas fire and need to raise the opening. It currently has a metal bar as the lintel. If I am to install a new concrete lintel are the ones with a section of 100mm x 140mm up for the job? It’s a ground floor gas fire and the house is 2 stories. Current opening 900mm...
  5. Jamespf1

    Bolt hole size for PFC

    Hi all, What size bolt hole should I be drilling for PFC to attach timber to to hang rafter to? The steel is 4m but doesn’t hold a lot of weight. Pfc section is 150x90x24 Thanks
  6. Jamespf1

    We Steel beam install first floor

    Hi all, Fitted a few steel beams before on ground level but not on first floor.. How do I setup acros on the first floor? Do I install them sitting on the floor joists with a board running across the bottom? Do I need to setup across on the ground floor as well? Directly under the acros on...
  7. Jamespf1

    Steel beam install first floor

    Hi all, Fitted a few steel beams before on ground level but not on first floor.. How do I setup acros on the first floor? Do I install them sitting on the floor joists with a board running across the bottom? Do I need to setup across on the ground floor as well? Directly under the acros on...
  8. Jamespf1

    Aluminium coping

    Hello all, Will be installing aluminium Coping on my flat roof soon. From what I’ve read it is the norm to install marine plywood 18mm under the clips for the coping. Is this necessary to install plywood? Under the flat roof is chipboard. Can I get my fixing into the is for the clips? Thanks
  9. Jamespf1

    Plastering times

    Hello, Going to give plastering a go but before I do I want to make sure my times are roughly correct. Pva the wall 4:1 - allow to go tacky 1.Apply first coat then flatten straight after 2.Wait 20 minutes 3.Apply second coat (slightly thinner) and then flatten out straight after 4.Wait...
  10. Jamespf1

    Patio door cavity filling

    I put a wide DOC at the bottom and up the sides and filled I’m with concrete. Was about 150mm deep. Can’t remember if I put insulation at the bottom
  11. Jamespf1

    Plastering over timber beams

    Hello all, What’s the best way for me to plaster over this timber beam? The ceilings are lath. The wall has a very thin coat of sand and cement followed by another thin layer of plaster. A 9.5mm plasterboard sticks out too much over the wall. There use to be coving covering this. Many thanks
  12. Jamespf1

    SLC cracks

    Hi all, Is this something to be concerned about? Got a couple of hairline cracks on my SLC. Screeded base underneath from when the property was first built. What would be the answer rack out the crack and re-fill or would I have to break a section up and re-fill? Going to have LVT over the...
  13. Jamespf1

    Laying self levelling over wet screed

    Hello, Can I lay self levelling compound over screed that was poured 24hrs ago? I understand this will slow the dry rate down but that’s not a problem. Thanks
  14. Jamespf1

    Patio door cavity filling

    Hi all, what can I do to bridge between my patio door cavity? Can I do L sharp with DPM running up the back of the patio door side and filling with screed? thanks
  15. Jamespf1

    DMC across door way. Levelling floor

    Hello all, What should I do here? Ripping up a high area of my internal floor near my patio doors. And can see my DPC from inside. What should I fill between the the courses of brickwork? And do I need to lay any more DPC/M anywhere else? Thanks
  16. Jamespf1

    Connecting Thermostat to boiler

    Awesome thanks! In 0.75mm?
  17. Jamespf1

    Connecting Thermostat to boiler

    Hi all, What cable do I need to run from my thermostat to combi boiler? Will only be using the thermostat for radiators. Thanks
  18. Jamespf1

    Angled drain off valve

    Hello, Can I use this Angled drain off valve as a TRV? Or does it have to go on the lock shield side? Thanks
Back
Top