    Block or Stud Walls - is builder correct?

    that seems a long winded way of doing it why cant you just have blockwork with 100 mm cavity ??
  2. T

    Wall plates? I'm desperate!!

    slate all tiles mate just bed on with mortar
  3. T

    section 52 ???????????

    can someone please explain what a section 52 is as its holding up the sale of my house cheers
  4. T

    Garage to House Slab Advice

    if your pipes are that far below ground I cant see it being a problem
  5. T

    Builder removed outer leaf of old external wall - safe?

    what about the steel did he extend the bearing ??
  6. T

    Pre cast padstones

    can you not use a concrete lintel ?
  7. T

    Damp Patch on Parapet Wall

    ah yes forgot about them plastic jobs, however is their enough brickwork their to put them in ? whats the reason for putting a stepped flashing in couldn't the brickwork be lower so the lead upstand went straight under the coping ??
  8. T

    Damp Patch on Parapet Wall

    its looks like there is no dpc below copeing stones , and why have they built the brickwork that height ? you cant put a tray in stepped brickwork
  9. T

    non standard size brick

    try your local reclaim yard
  10. T

    Foundations

    yep raft is ok ,but why the 2 skins ?
  11. T

    2m x 12m freestanding boundary wall

    I agree with jeds apart from the 150 mm I would go for about 250mm to 300 mm depth
  12. T

    Air Brick Problem

    can you post some pics up as from what your saying it dosnt sound to good, your new blockpaving should be below your dpc level and your air bricks should not be blocked
  13. T

    DPM or Not

    for the sake of a roll of poly I would put it down followed by insulation then screed
  14. T

    building inspector control - concrete cold weather

    plus 5 will be fine for footings mate
  15. T

    Brick garden office with cavity/Help required for materials

    mp looking at my early morning post I think I might be a bit light ,! I would go for 4 bags of sand and 30 cement mate !!
  16. T

    Brick garden office with cavity/Help required for materials

    my estimates are for brick and blockwork only
  17. T

    Brick garden office with cavity/Help required for materials

    for 1500 bricks = 1.5 ton for 700 blocks = 0.7 ton so I would go for 3 x tons bags and 25 bags of cement 5 litres of febmix :D
  18. T

    lead tray in chimney

    hello if you were building a chimney stack on a new house, where would you put the lead dpc (s) the chimney is flush with the outside skin and dead center of the roof .
  19. T

    Raised Patio - DPC needed?

    if the damp is not going inside the house then there is no issues , however if your that woried its quite easy just to insert a dpc in the bed joint 150 mm above the patio. ps if its a tiled patio do not go on it while its wet !!!!
  20. T

    25 year old house without planning

    ive had to go for the indemnity ,just to speed things up the house has been on the market for a long time and the buyer is getting itchy feet cant afford any messing about, estate agent said its because the upstairs didn't come under building regs at the time , as it was signed off as a single...