    boiler-worcester greenstar i system compact unvented cyl- stelflow pre plumb 300l stat- led p5 TQX0073 Electronic dual cyl stat ESCTDEPW 3 channel multi purpose prog TQX0027 A prog, stat and the cyl stat are all supplied, and are connected to a wiring center located on cylinder. 2 port...
  2. Groovejet

    baxi 80he instant 50' flashing

    ill have to find out exactly but dont know if he manually tricked aps into ignition while fan was working? thats what i would of done,
  3. Groovejet

    baxi 80he instant 50' flashing

    Boiler pump starts ,micro switches make but nothing else. Has anyone come accross 50'light showing fault but fan , pressure switch and pcb are good, my colleague is less experienced than me but he's Gas safe. I told him to test flue over heat stat. And if needed link out stat to test. He says...
  4. Groovejet

    baxi105 he hw cycling

    Boiler sorted , removed divertor . Cleaned everything I could get to ..pipes by pass .. venturi. Flow . Return pump and moved plunger on divertor by hand to free up. Boiler now stays on and Temp in hot water stays on 70' . No cycling . Removed minimal dirt and it's ok. But it was a fine line...
  5. Groovejet

    baxi105 he hw cycling

    Gas check passed ,he adjusted the min rate. Max and min were 12 mbar. Still cycling on off though. I went and put x300 in last night . I could here a slight kettling noice. Very low though . And also when kitchen tap was on and burner was ramping up heating it , a couple times I noticed a...
  6. Groovejet

    baxi105 he hw cycling

    Checked again and after cleaning condensate makes me think it's the secondary heat exchanger?? If the condensate had loads of dirt then so should that, shouldn't it? Have to get my mate to clean it when he does the gas check. Obviously I want to put him in the right direction. There isn't much...
  7. Groovejet

    baxi105 he hw cycling

    Venturi clean and the everything looks clean. Apart from condensate . There is a lot of residue like wet washing powder. Cleaned that out. Havnt tried it yet. Even though no one has tampered with the gas valve . Could it be overgased ? I'll tell him to get a fitter I put him onto for that. The...
  8. Groovejet

    baxi105 he hw cycling

    What happens when I take out the Venturi at tea time and it falls apart?? Refitting it broke! Will boiler work?
  9. Groovejet

    baxi105 he hw cycling

    Ok thanks. I just explained the long winded way. Lovely.
  10. Groovejet

    baxi105 he hw cycling

    If the cw inlet to boiler is shut, what do I open hw tap for? Is it just to drain the water out the hot side? How does it work ? Being set on middle ground does that somehow islolate the cold on a working shower? But pass water if it's broke? Otherwise I don't know. Thankyou Ian Sounds like a...
  11. Groovejet

    baxi105 he hw cycling

    yeh thankyou. ive got a flow cup. but never used it here. The temperature is very hot(thats technical for didnt measure temp at all.... very hot) See what your saying .....With a lesser flow rate at tap, boiler will cut out or show its problems more. Had txt today that shower has stopped...
  12. Groovejet

    Baxi 105e no DHW

    iknow its old thread but rather than start all over what was the outcome?
  13. Groovejet

    baxi105 he hw cycling

    Right , been back and replaced both thermistors while i was there. Also removed pump head , seemed very hot.....dirty and abit of shale but nothing realy . But enough to make a guess that primary hex is dirty also. Boiler still hits 80' and goes off but cools for 30sec or so and comes back on...
  14. Groovejet

    baxi105 he hw cycling

    so if the divertors look the same what is the differance? Is the divertor blanked off internally on tha by-pass, that would make sense ??
  15. Groovejet

    baxi105 he hw cycling

    dont understand that then? Baxi 105's have the 22mm by-pass pipe with the little pigs tail sensing pipe on it.! So how would there be 2 differant divertor setups?? For 2 differant Baxi boilers?? Or actually for the 105's?
  16. Groovejet

    baxi105 he hw cycling

    not a problem
  17. Groovejet

    baxi105 he hw cycling

    Thanks Ian, thats a good trick simply using hand heat as a base for temperature as such....37':mrgreen:
  18. Groovejet

    baxi105 he hw cycling

    Yes you did hit a nerve number 1. Im not trying to be a clever sod,. The only reason i can have a good hit rate fixing boilers because i can put the time in to fault finding etc. These jobs i get arnt paid work as such. They are family and friends who know a handy guy and i also love fixing...
  19. Groovejet

    baxi105 he hw cycling

    Thankyou ian for your respectful input, and yes very good point i didnt take temp. As my infra red thermo. doesnt seem accurate so i stopped using it. Its brand new mind, from Plumb Center, Brand Tpi or something. Anyway so i seen a noticable drop with temp rise from 9k-11k down to 4k. So i...