  1. B

    Syphoning problems

    The bases are at the same level
  2. B

    Syphoning problems

    Here is an extremely rough sketch of the way I have it set up.. It keeps on pushing water into the second tank when the main tanks pump turns off.. Can anyone tell me an easy way of stopping it from syphoning i.e something I can put on the pipe within the main tank just before it comes...
  3. B

    Syphoning problems

    the outlet pipe from the main tank is about 1.5 foot above the inlet on the second tank and well above the pump in the main tank..do you have any links to some anti syphon vales? Thanks
  4. B

    Syphoning problems

    Hi all, I have a main tank with a pump in it pumping into a smaller tank. When the pump in the main tank turns off it continues to syphon down into the smaller tank. I am using a float switch system that I would like to turn on the pump within the main tank when the second tanks level gets...
  5. B

    Fixing 2 x bilge pumps inside plastic 25 gallon loft tank

    Very good idea... The trouble is the plastic sheet thats glued to the bottom of the tank can never come off again...melting the hex nuts into the bottom of the sheet might work though so if the pumps ever need replacing or cleaning I could screw back down into them. It would be a lot...
  6. B

    Fixing 2 x bilge pumps inside plastic 25 gallon loft tank

    Hi all, I am working on a project and need to screw 2 x large bilge pumps to the bottom of a 25 gallon plastic loft tank...here is the tank http://www.bhl.co.uk/product/POLYTANK_PT2000_27X20X20_25GAL_RECT_INS At the moment I have stuck a piece of plywood to the bottom of the tank using...
  7. B

    Banging head off wall CCTV Mic problem

    A google suggests the one you intend buying (a) comes with a 1/4" plug adapter, and (b) runs off a watch battery, which may need rather frequent changing. The guy from tech support seems to think one battery will last for 1000 hours....I think this is a bit adventurous..but at 76p a battery...
  8. B

    Banging head off wall CCTV Mic problem

    Thanks for your reply.... The CCTV mics ive seen dont look like they will pick up a good all around signal. So it would seem I need to use the pre amp and things are getting complicated..As I see it to use the amp I will need to get a 1/4 inch jack - 3.5mm jack converter...
  9. B

    Banging head off wall CCTV Mic problem

    Hi all, I am trying to connect a mic to my 4 way cctv dvr unit of which has a mono audio in and audio out BNC socket. Today I bought a set of pc speakers with amp in and connected it to the mono audio out via BNC to phono adaptor - phono to 3.5mm jack socket adaptor and the speakers are...
  10. B

    Lights Flashing With Dimmer

    Hi, I installed the whole lot from new i.e wall lights, switches etc.... Im actually an NIC Approved contractor but have never known dimmers to flicker like this. As I said in my last post its a 60-250W dimmer with 60W lamps on and was wondering if anyone has ever come across this before I go...
  11. B

    Lights Flashing With Dimmer

    Hi all, I recently installed a 3 gang MEM dimmer switch rated at 60W - 250W in a customers house. The customer bought the dimmer switch from B&Q. Its rated 60-250W for each gang of the switch. When I first fitted it sometimes the 60W wall lights would flicker on and off then eventually stop...
  12. B

    Lockable Room Stat

    Thanks for that will order one of those tomorrow!
  13. B

    Lockable Room Stat

    Hi, Thanks for the reply. I mentioned putting a cage or a lockable case over the stat but the customer would prefer a proper lockable cover or one with a code you have to enter to change the setting. Im sure there is such a unit as I saw one somewhere a couple of years ago? Thanks Alex
  14. B

    Lockable Room Stat

    Hi all, Im an electrician and went to look at a job yesterday where the client would like the central heating room stat to be locked so it cant be turned up by the tenants. Its a huge house with 12 bedsits/studio flats and the room stat is in the communal hallway. Ive heard you can get either...
  15. B

    Double Glazed Windows With Wooden Frames And Sills Left In

    Hi all, Im going to view a flat tomorrow that is double glazed but the old wooden window frames and wooden window sills have been left in. It was an old lady who lived in the house who is now in a home so theres every chance she has been ripped off by a window fitter who has charged her for...
  16. B

    Horstmann BX2000

    Hi all, Im an electrician and have a customer with a faulty Horstmann BX2000 hot water controller. This basically has on peak supply, off peak supply, 1 hour boost, 2 hour boost, controls 1 imersion element, has an on peak switch and off peak switch. The customer wants the cheapest...