  1. C

    heatmiser UH3

    Thanks Dan, I am doing what you advised during my last thread about actuators etc and ripping the old out replacing with new Paul
  2. C

    heatmiser UH3

    A quick question about the above wiring centre, I have just bought it to upgrade my system and I am stumbling on the first hurdle "how do you get into it!" I don't want to damage it but the literature with it goes straight into wiring. Thanks for any info Paul
  3. C

    L641B1012 pipe thermostat

    The Man boiler is using a low temp output and the system also has a Reliance blending valve but I will fit the overheat thermostat as you state. Thanks for the interest Paul ps, in the event of a problem with this boiler (28kw htg 36kw DHW) what would be a good alternative to replace it with and...
  4. C

    L641B1012 pipe thermostat

    Dan, The Eco manifold wiring diagram that I posted was the "norm" back in the year 2000 when I installed the UH system, I can see the benefits of today's wiring centres but my system has been trouble free over that time so there has been no need to upgrade. The water system has all the features...
  5. C

    L641B1012 pipe thermostat

    Dan, The manifold wiring diagram supplied by "Eco" was what I used to build up my drg as e-mail (don't ask why the pipe stat is where it is shown on the drg I haven't an answer but it's been there years) What I intend doing is to place one wire of the o/heat stat with the orange wire of the zone...
  6. C

    L641B1012 pipe thermostat

    Dan, the system was supplied by "eco-hometec (Doncaster)see drg. attached
  7. C

    L641B1012 pipe thermostat

    The problem wasn't the CM67 as this was not calling for heat (showing no volts on my meter in the junction box) There are three master actuators (four wire Honeywell Z 100) and individually checking each one I found one "live" sending power to the Zone valve, pump and boiler. (I presume the...
  8. C

    L641B1012 pipe thermostat

    Looking for a bit of advice, forum members, I have a 10 zone underfloor heating system and had a problem yesterday when a faulty zone actuator left the heating system working when the CM67 programmer was not calling for heat. I want to fit the above thermostat (which I have) in the system so...
  9. C

    Vibration

    Please advise, My neighbour has a tee off his kitchen sink cold water supply that feeds a filtered water unit and he says that occasionally there is vibration on the pipe for no obvious reason, ie, the hot or cold water supply has not been used immediately before, during or after this occurs...
  10. C

    heating valve replacement motors

    Thanks boilererman 2 for your response, I was given the cost for this item by the service eng. so I e-mailed MHG for the price and their response is that the actuator is now only supplied with the valve attached hence the price £390 to pay + delivery. I am now back on the trail of repairing...
  11. C

    heating valve replacement motors

    A question on replacement motors, I have a diver-tor valve in a Mann gas central heating boiler (supplied by Eco homtec in 2001) and it is powered by a synchronous motor similar to the Honeywell 4043H valve motor, the difference between the two being the longer length of the gear wheel shaft of...
  12. C

    CM 927 installation

    Thanks Dan, Don't ask why I didn't look at the wiring diagram for zone valve control because I don't know what I looked at but obviously not that. Both zones are now working from the two stats. Just waiting for the plumber to fit the boiler for my neighbor Thanks again Paul
  13. C

    CM 927 installation

    Please advise on the following, While I am waiting for the plumber to change the boiler I require pointing in the right direction with the CM 900 wireless relay box. I have powered the relay box L & N to mains and have it responding to the 927 stat heat demand (stat to relay) I have then...
  14. C

    440CDi combi control

    I have always used Honeywell hardwired controls in the past and found them reliable and long lasting but using the wireless components makes it easier than chasing out plaster and running cables through rooms, providing there are no issues with "control and reliability" They are not cheap to...
  15. C

    440CDi combi control

    Thanks Picasso its straight forward looking at the drg. The power supply to the controls are through LS with LR the switched live thus no other supply is needed apart from the supply to the boiler if i read your drg. correct. Do you have any experience of the Honeywell wireless stats /...
  16. C

    440CDi combi control

    We are upgrading a heating system from a single circuit to a "two zoned" circuit and instead of chasing out plaster to hardwire thermostats I was thinking of using the Honeywell CM927 wireless programmable thermostats controlling each of the circuit zone valves A "gas safe" plumber is...
  17. C

    Modulating boiler problem

    I agree with you that when the repair cost starts to escalate then it's time to replace . I did look into a Bosch alternative which, if I have bought it would have required an external three way diverter valve installing to give me what I required, according to Bosch technical. My boiler has...
  18. C

    Modulating boiler problem

    Thanks for the response, This boiler "Micromat" is a German made boiler also sold under the name Strata, but is now superseded by the ProCon 77 according to the MHG web site. With regards to modulation the fan, burner and water pump modulate I am a Mechanical Engineer by profession and I am...
  19. C

    Modulating boiler problem

    Hello forum, could you please advise on the following, I have a Micromat HS 31kw condensing boiler((bought from eco hometec Doncaster, (who have gone into demise)about 10 years ago when I installed underfloor heating in my house)) and it is cycling between hot / cold every approx 2/3...
  20. C

    wet room and boiler query

    I have a problem that I hope can be resolved without too much expense. I have a Bosch 28I junior that is running the DHW and heating in a holiday cottage (kitchen sink, and two shower rooms) The problem is that when the shower is in use the hot water periodically coolsat the shower head (as...