    Texecom 48 install....East London

    Excellent. Thanks So pretty much on the Network port, at the moment I have 2 Keypads already connected now this making it the third. All dips are set to different settings
  2. T

    Texecom 48 install....East London

    Hi Alarm Another slight problem. Where do I wire the 32XP-W Theres 4 wires, 12V 0V T R, not sure were to put this in the control panel? The wireless expander will control Main door Garden Door Utility room Door Utility room PIR and 4 wireless key fobs. In the whole process...
  3. T

    Texecom 48 install....East London

    Excellent, thanks just want I needed to know
  4. T

    Texecom 48 install....East London

    Hi Alarm Still slightly confused. I understand its the first and last terminal in each zone setting. But do I put a resistor 4K7 and 2K2 resistor in as well i.e. Take the 4K7 and 2K2 resistor, twist one of the legs together with the other. Free leg of 4k7 and a blue wire goes in at the...
  5. T

    Texecom 48 install....East London

    Hi All First problem.... Have installed all the PIRS and configured the jumper settings on the PIR to EOL. Do I now put the blue and yellow wire directly into the premier 48 panel or do I configure it with the 4ks and 2ks jumpers?
  6. T

    Texecom 48 install....East London

    Hi Guys Thanks for your help. Guess big day tomorrow when I kick start the implementation. I had a quick play with the Ricochet software which looks straight forward for registering the devies. I couldnt get my head around the wintex software. Is there a template that is available I...
  7. T

    Texecom 48 install....East London

    Thanks Alarm Ive decided to make the wireless section the first set of Zones considering its all on the ground floor. Just slightly confused on how I go about installing the Wireless Expander and programming the zones.
  8. T

    Texecom 48 install....East London

    Hi Alarm Quick question regarding the zoning. You mention you tend to start of using the front door as being Zone 1 and so forth. The front door, Garden Door and Utilitiy Door is part of the Wireless Expander do I use this first to start of the Zones? Or do I go hardwire zones first then the...
  9. T

    Texecom 48 install....East London

    Thanks for getting back. Ok will search the web for NACOSS/SSAIB website. Spoken to a few sparks and they dont any of this, especially the configuration aspect. I dont mind doing this myself, Only problem I see is configuring wintext and the wireless expander. Looking at the PIRs which...
  10. T

    Texecom 48 install....East London

    Hi Joe, Yes Im in London. Im assuming the other person your talking about is Alarm. Havent herd nothing back . Looks like I will have to go solo and attempt it myself. Im confident that I can do it but the configuring of the wintex/ zoning will need help on.....
  11. T

    Texecom 48 install....East London

    Hi Any recommendations for installers.....
  12. T

    Texecom 48 install....East London

    Hi Yes I have all the equipment 1x 48 Premier Panel 2x Premier LCD Keypads 1x Wireless Expander 32XP 3x Richochet Wireless magnetic contacts 4x Premier smartkey wireless fobs 8x Prestiage DT PIR 1x Premier GSM Module 1x Speach dialler 1x Remote mic 1x Odyessy compact sounder...
  13. T

    Texecom 48 install....East London

    Hi Not sure if this is the right place to ask.......... I wanted to find out if anyone can recommend anyone to do a Texecom Install in East London. All the cabling has been laid to the correct positions due to the flooring/ plastering taking place. Wiring all goes back to the Premier...
  14. T

    Quartz Tiling in Cement

    Hi All Need some urgent advise on Quartz tiling. My dining and kitchen floor is 65sqm and very uneven. The old tiles were removed today. The floor needs to be raised by just over an inch/ inch half aswell. The tiler said he will raise the floor and level it out using screed. But at...
  15. T

    Clear varnish on American White Oak

    Hi The problem with them is that there useless. Everytime ive asked the reply I get back is its your choice. Everyone has their own choice of colour, method so its really up to you........ So not much help. Hence why I turned to this forum for advise.
  16. T

    Clear varnish on American White Oak

    Hi All Any suggestions on the below......
  17. T

    Clear varnish on American White Oak

    Hi All I purchased a test pot of the Osmo Polyx Oil Clear Satin and a small pot of Shellac The result was excellent compared to the Clear Varnish. I think I will now go down this route. Before I purchase the tins wanted some advised In terms of prep work do I Fill the holes etc in...
  18. T

    RCBO trips RCD

    He did give me some papers which he completed and some copies of the paper which he took. Cant remember the name of the paper. I should have done the testing or verified it but TBH as the lights and sockets were working I didnt check as had so many other issues Ive been trying to sort out...
  19. T

    RCBO trips RCD

    Yes :cry: Ive paid him all the money which was a substantial amount. As the job was complete I didnt think of testing or verifying all the bits and pieces on the CU. I noticed it last night whilst clearing up....then again I havnt checked the RCBOs on the main consumer unit...
  20. T

    RCBO trips RCD

    Your right. It was finalised this Friday and he signed off the paper work. Also mentioned to wait 2-3 weeks where I will get some sort of certificate. He done all his testing etc etc. I only noticed the problem last night when I switched on the RCBO as it was off, thats when the RCD...