  1. T

    Electric underfloor heating issue

    ok cool thought as much, thanks what a headache... next time wet underfloor heating system!
  2. T

    Electric underfloor heating issue

    Hi there Got a problem with my electric underfloor heating that my builder installed in 2013 It's a Heat Mat installation below tiles, controlled via a KNX switch that turns it on for a set amount of time (via a KNX actuator). It's in the bathroom but there doesn't seem to be any cracks in...
  3. T

    Texecom entry question

    thanks very much - will change that!
  4. T

    Texecom entry question

    hi all quick question to check why this entry time isn't working as expected in my garages. so Area A is set as a Timed Exit, Entry 1 Delay Time and Entry 2 Delay Time are set to 120s. Area A has a: garage door contact set to Guard Access a PIR set to Guard Access and to Double Knock too a...
  5. T

    Texecom Elite 48

    Thanks for the help everyone The replacement battery arrived before I had chance to sort out the multimeter and everything looks like it is working fine now... looks like the previous battery, even though 9 months old, was knackered
  6. T

    Texecom Elite 48

    No I haven't measured any of that stuff. I'll buy a multimeter and see what they are. Strange it would start happening out of the blue, the devices on the system haven't changed for a long time.
  7. T

    Texecom Elite 48

    Yes I think you're right maybe not the battery. I will check the jumpers this evening but quickly in the morning I checked the logs and I had low voltage warnings expanders 2, 3, 4 overnight. This is without the "faulty" battery connected. The fuse it not lit red but I guess I will replace it...
  8. T

    Texecom Elite 48

    Battery terminals were fine. It's been working fine for 9 months, nothing touched it. It is a Texecom PSU200. The battery is the same model as the original installer put in the main alarm box so I bought the same when I added the extra PSU What I didnt understand is normally if the battery is...
  9. T

    Texecom Elite 48

    Fuse in PSU 2 was not lit red but the battery fault red light was on. For the time being I disconnected the battery and will order a new one
  10. T

    Texecom Elite 48

    So just now my alarm went off out of the blue whilst I was in the house, put in code and there were a bunch of items. I downloaded the log and it looked like earlier today in the afternoon there were some battery issues too: ... The system is configured with a battery in the main box and...
  11. T

    Texecom reset after a few seconds

    OK cool thanks, that makes sense Texecom said options 26 and 27 only apply to full set, but what happened here is as you say contradictory to that - which is what had me a bit confused!
  12. T

    Texecom reset after a few seconds

    Hi there A little mystery... not sure what's going on here. Premier 48 panel and Part Armed overnight When disarming system in the morning I saw that a zone had been active overnight on the keypad. The logs: So what exactly does this mean? I can't remember hearing the internal or external...
  13. T

    Alarm outputs into home automation systems

    It looks like soon you'll be able to integrate Texecom directly with Z-Wave and a bunch of other stuff: http://www.texe.com/uk/technology/connect/ A more expensive option is Control4 (although if you buy a second hand HC250 controller off ebay and find a cheap integrator it's not ridiculous)...
  14. T

    Texecom alarm triggered

    So reply from Texecom (very promptly I must say, excellent service): Configuration 26 and 27 only apply to full set operation, part sets will operate as normal even with these options enabled. As a workaround for this you could either turn your part set into an area or use the beam pair...
  15. T

    Texecom alarm triggered

    Yep I have set the digi output for thee text/speech dialler to trigger on Confirmed Alarm, and I didn't get a text. I doubt I got to the keypad before it managed to dial and connect to the SMS centre too. Option 35 is worded like this in the manual (it's not clear if you tick it which on of the...
  16. T

    Texecom alarm triggered

    yes a bit confusing... I take it's nothing to do with option 35 being checked?
  17. T

    Texecom alarm triggered

    It was the internal sounders for sure, don't know if the external bells went off too
  18. T

    Texecom alarm triggered

    hi there had an issue a few days ago where one of the PIRs in a garage was triggered by something moving in the garage, which caused the alarm to go off. The garage door, which has a door contact on it, remained closed. Both the PIR and the door contact are set to guard access. I was expecting...
  19. T

    Texecom alarm triggered

    Thanks Part Arm Coms was empty... I've added the zones to that now "Bells on Confirmed Alarm" is indeed selected. So in this example, the alarm didn't go off because the same PIR (or any other) was not triggered twice within the confirmation window, but the keypads kept beeping all night...