  1. J

    Which oil-fired condensing boiler?

    Good point, I may well do the 2 smaller boiler option. Like you say, there will be back-up should one be out of action
  2. J

    Which oil-fired condensing boiler?

    Does anyone know of a good 80kW oil fired condensing boiler? I know Worcester Bosh do a 50-70kW, not sure if they do an 80kW version?
  3. J

    Fire rated cable?

    Is Low Smoke Zero Halogen (LSZH) single insulated cables to BS7211 a fire rated cable? Or is this considered as an insulated fire cable?
  4. J

    Gas Pipe in screeded floor

    Thankyou for the info
  5. J

    Gas Pipe in screeded floor

    Good stuff. This is all well and good, but what happens if joints are unavoidable or not practical?
  6. J

    Gas Pipe in screeded floor

    Thanks, I was meaning wet underfloor heating. Regarding the joints, the 3m length copper pipes would need to be jointed, so there is no way round this I assume? Or I may be wrong here
  7. J

    Gas Pipe in screeded floor

    What are the current Gas Safe regulations for installing copper gas pipework beneath the screed? Is there just a requirement to wrap in protective Denso tape. Are joints or connections an issue under the screeded floor? Are there different regulations if the screed also contains underfloor...
  8. J

    Cabling routes/joints??

    Could anyone please advise what the current IEE / Part P regs are when installing cabling beneath suspended timber floors i.e. in the floor of a bungalow. Should they be neatly clipped to the side of the joist. What happens if a joint is needed in the cabling, is the standard method of...
  9. J

    Pipe insulation??

    Hi, What (if any) are the advantages of foil backed pipe insulation as opposed to standard black pipe insulation.
  10. J

    Frost Protection?

    Good point! Well I guess that is something put on a notice next to the boiler in big letters!
  11. J

    Frost Protection?

    Thank you all for the comments. Presumably this set up / protection overrides any other settings which the user may set on the programmers and stats?
  12. J

    Frost Protection?

    The boiler/system is on a weather compensator so it should activate when the outside temp drops below 3degC.... at what point does it fire the boiler?
  13. J

    Frost Protection?

    Could someone explain how the 'anti-frost' mode works on Vaillant boilers? Does this activate the boiler / heating system if the temperature drops below X deg C? Thanks
  14. J

    Upgrading from single-phase to two-phase?

    Thanks, yes I think the nearest 3-phase network is half a mile away and the cost to bring it over the hills to the transformer was ten's of thousands! So I guess what you are saying is that we're stuck with the 240V single-phase unless we want to spend big money?!
  15. J

    Upgrading from single-phase to two-phase?

    The pole is only 50 metres away but I think the supply to it runs about a mile over the hills (and this could only be a single phase supply). Not entirely sure how it works, can you take a 1, 2 or 3 phase supply from a transformer full stop or does it depend on what type of supply is supplying...
  16. J

    Upgrading from single-phase to two-phase?

    The house is in the sticks somewhat and currently fed via a single-phase supply apparently the nearest three-phase is available half a mile away. There is a dedicated pole mounted transformer on the end of the overhead supply, are they able to take the second-phase from that?
  17. J

    Upgrading from single-phase to two-phase?

    How easy is it for the utility company to convert from a single-phase electricity supply to a 2-phase supply. What is involved? Apparently this may be more cost effective than a new 3-phase supply. It is a large house that may require more than a single-phase supply can cope with. However...
  18. J

    Gas supply

    Thanks, so WHO sets the rules and regulations for taking the relevant precautions to keep the gas supply in place, if its not Corgi????
  19. J

    Gas supply

    What are the CORGI regulations on this? I would like to know it can be done safely first
  20. J

    Gas supply

    Thanks. I am not a RGI but I was curious as to what precautions were needed in order to allow it to remain in place.