Search results

  1. M

    shed light and socket maybe

    Hi all. Im in the process of building a new shed/summerhouse. Im going to need a light forddefinate and a socket would be nice too. I currently have a outdoor socket fed from a switched fused spur with neon light inside the house. What would be the easiest way to get a socket and light to the...
  2. M

    2 bedroom wall lights to a plug?

    Hi all, I've aquired a couple of cube wall lights off my mum who throwing them out,brand new in box,with no wiring guide.. My other half wants them for either side of our bed. I don't really wanna Chase all walls as we've not long since decorated,so was wondering whether it would be ok to...
  3. M

    no hot water to loft en-suite basin

    picasso....now i feel like a right numpty. was full of junk even what looked like a tiny twig....tap running perfect now. sorry guys. thanks for the help mark
  4. M

    no hot water to loft en-suite basin

    meant low pressure to the en-suite
  5. M

    no hot water to loft en-suite basin

    sorry do you mean other taps around house?kitchen and family bathroom. i can obviously tell you now that its a hell of a lot slower than the other hot taps in the house. maybe i have the wrong type of tap as i`ve just been on ebay and seen a similar tap what says not suitable for low...
  6. M

    no hot water to loft en-suite basin

    just thought i forgot to say its a a single lever basin tap....and when i put it on cold its the same pressure as when i turn it to hot. the cold feed also supplies the toilet and shower which don`t suffer from low pressure.....thus making me wonder whether its the tap. can i strip this type of...
  7. M

    no hot water to loft en-suite basin

    a worcester junior 24i
  8. M

    no hot water to loft en-suite basin

    hi all i have a problem with my en-suite (situated in loft)basin mixer tap. i just cant seem to get hot water....the boiler doesn`t kick in when tap turned....thats what happens when i turn on any other hot tap in house. could it be the tap? i have a combi boiler and its set on economy. if i...
  9. M

    shower wiring

    my sincere apologies mate. thanks for the advice anyway
  10. M

    extractor wiring from junction box

    1mm i meant
  11. M

    extractor wiring from junction box

    if i take a spur from junction box do i take it from circuit L+N with 1.5mm cable to a FCU(3 amp)then 1.5mm to fan
  12. M

    extractor wiring from junction box

    i understand what your saying m8...but surely i can just leave the extractor running and turn light off,rather than leaving light with extractor running for a while...the fan hasdn`t got a timer or anything.
  13. M

    extractor wiring from junction box

    hi all, im trying to install a bathroom extractor fan outside my cubicle..its currently set to come on with the light switch....very annoying. the lightiing circuit is on a junction box with both circuit cables,light cable and switch cable(and currently cable for fan) can i just disconnect...
  14. M

    shower wiring

    40b m8
  15. M

    shower wiring

    yeah the main water line coming into property is earth bonded.and as you say the water pipe is cold only so won`t cause any heat to damage cable sheath.... thanks very much chri5 cheers magico
  16. M

    shower wiring

    hi just wondering if you could put me mind at rest(hopefully). the shower in the ensuite - the cable and pipe are next to each other in the studded wall,they are touching..the cold water pipe is copper then pushfit pipe the cable sheath is in perfect condition.....are there any safety issues...
  17. M

    plinth heater

    hi all, just a quickie.... my brother just brought round a plinth heater which he had stashed in his shed...is a plug with 13 amp fuse suitable to connect....sure its anything upto 3kw before hard wire.....heater works between 2200 - 2400 w cheers mark
  18. M

    removed a shower

    no not gonna use it for anything else m8 so its ok to leave in till i get a blank and i`ll disconnect the earth in morning.. safe over night then? its only the earth afterall
  19. M

    removed a shower

    i disconnected live and neutral and cut back as far as i could,the earth is still connected and the fuse still in. should i remove earth cut back and remove mcb or leave in?
  20. M

    removed a shower

    after reading a few other threads i guess i should disconnect earth,cut back and remove fuse and use a blank plate to cover am i right?and is it safe the way it is till i get a blank any advice much appreciated
Back