  1. C

    Query with correct pipe size for c. heating to new extn

    Do you mean sleeve the copper 15mm pipe with 22mm copper pipe or use plastic?
  2. C

    Query with correct pipe size for c. heating to new extn

    Also forgot to add when the pipes go under the screed do they get wrapped in the hessian type material or foam lagging?
  3. C

    Query with correct pipe size for c. heating to new extn

    Hi all, I'm having a new kitchen extension built and (4.2m x 3.4m) and have worked out I need a 7000 btu rad.(1200mmx600mm). Would I run 15mm pipe to the new rad from my house or 22mm pipe to the radiator and then 15mm to the radiator ends?
  4. C

    Potterton Kingfisher - clicking/surging noise

    When the room has reached temperature and boiler clicks off or when water reached temperature and boiler clicks off, the boiler makes a clicking noise/surging noise, then when temperature in room calls for heat boiler fires up fine and runs ok. Any ideas on clicking noise? Also want to put...
  5. C

    No Central Heating & Pump Overun Question

    Thanks Chris, replaced motor in head and heating now working. Pump not wired into boiler so will do that. Thanks again
  6. C

    No Central Heating & Pump Overun Question

    I have a house which I rent out, Potterton Kingfisher boiler, fully pumped system,Grasslin contractor pack QE2, all installed about 6 yrs ago. Currently there is no central heating, the tenant said there has always been a light on the room thermostat which is no longer working and the hot...
  7. C

    Heating/Hot Water problems

    Thanks for replying, will go through your answers over Christmas, luckily I can operate CH and HW even though not together.
  8. C

    Recommendation for a combi boiler ? - rented flat

    The reason I asked for recommendations is that I would rather pay extra to get a boiler that gives me no problems, of all problems I ever get with tenants it will be a boiler not working. A friend recommended Potterton hence asking about the Performa. Not all landlords believe in fitting...
  9. C

    Heating/Hot Water problems

    When I select 'ch only' on my control unit the lever on the three port valve moves over to 'H' and the pump switches on/off according to the thermostat telling the pump when the room has reached/not reached temperature. When I select 'hw only' on my control unit (central heating off) the...
  10. C

    Recommendation for a combi boiler ? - rented flat

    I rent out a two bed flat that has a very old boiler and I plan to replace it for a combi earky next year. Generally I find tenants tend to ring more often than not when boilers go wrong. Can anyone recommend a reliable combi boiler? Any thoughts on the Potterton Performa which I had a look...
  11. C

    Three port valve problem?

    Thanks for replies, which I can now go through to sort out.
  12. C

    Three port valve problem?

    Thanks for replies, sorry I should have mentioned it has been working fine up to now.
  13. C

    Three port valve problem?

    When I set my controls for heating only this works, when I set my controls for hotwater only this works, when I set my controls for central heating and hotwater only the heating works. Does this sound like a fauly three port valve?
  14. C

    Question about a transformer

    Thanks for all your advice, went for a 150w transformer with 3 x pairs of outlets - works a treat. Thanks guys :)
  15. C

    Question about a transformer

    Thanks for your replies, much appreciated, if I do decide to keep the transformer I have, do I connect two of the lights into two terminals of the output and the remaining lamp into the other two terminals of the output?
  16. C

    Question about a transformer

    Can swap for a larger transformer, no problem. There are the two terminals on the input, and four terminals on the output side in a line
  17. C

    Question about a transformer

    I want to run 3 x 35w low voltage lights off a transformer. I have purchased a transformer that runs up to 105w. It has 4 x terminals on the outlet. Would I run 2 x lights into two of the terminals and the last light into the other two terminals?
  18. C

    How do you light a C&M Corvec Miniflame 11 Boiler please

    Had a corgi plumber round today, who got the pilot light working (blocked) and the boiler firing up. The main flame would ignite and then die down, when he tapped with the base of a screwdriver (lower part of the boiler) the the boiler flame fired up again and then died down. He had not ever...
  19. C

    How do you light a C&M Corvec Miniflame 11 Boiler please

    It has a spark button (must be the deluxe version!) which is sparking when I look through the window but not lighting the pilot light, would you say it is the thermal fuse that needs replacing - where is it located please? Thanks