  1. G

    Keston Boiler Starting problems

    I work on loads of these boilers, normal problem is electrode and HT lead. Or sometimes the burner just needs washing with household detergent and rinsing through. Normally solves ignition problems. James
  2. G

    condemned boiler

    Seems a reasonable price, does it include proper cleaning of the system. The removal of old tanks, boiler and cylinder. What boiler are they intending to fit. James
  3. G

    Glowworm 30cxi and dropping pressure (Parts replaced)

    Sounds like you have a leaking heat exchanger, and the water is running straight out the condense pipe. See if when you isolate the boiler it should eventually stop, and nothing should come out the condense unless the boiler is running. James
  4. G

    ....talking of fga's.....

    Our company lease them with all maintenance and repairs, through a company called G.E.S. That might help James
  5. G

    Gas Meter Size ??

    Round this way it is mainly all still low-pressure, well in the majority of the smaller commercial premises. Only just started getting medium pressure in some new build areas. James
  6. G

    Gas Meter Size ??

    Just had to have an old peoples home upgraded from a u6 to a u16 they had a 70kw boiler, a 30 kw boiler, a 35kw water heater, and two commercial ranges. It cost the customer 5.5K to have a new service run as the existing will rarely be big enough, and two have a meter fitted. Although they...
  7. G

    probably a silly question

    A Screwdriver if its just a slot or an adjustable spanner if it is a lug. James
  8. G

    Ideal Mexico Super 2 Gas Boiler

    How does one "wake up dead". James
  9. G

    Tank overflow leaking........

    Sounds like the water level in the tank is set to high so as the water expands when the heating is on, it all starts to come out the overflow. Or your boiler thermostat is playing up and heating the water up to hot. James
  10. G

    Loud banging from around the whole house

    Do you have thermostatic radiator valves fitted, if they are installed incorrectly they can bang as they close down. Should the boiler have a pump overrun? James
  11. G

    Ideal Mexico Super 2 Gas Boiler

    Get it checked out, but don't get fobbed off with a replacement boiler, these are very solid and reliable boilers. One of my favourites. James
  12. G

    Alpha CB50 runs cool - please help.

    If I remember rightly these boilers have two prv's one for the system and one for the unvented store. Can you identify which one is letting by, could be a faulty thermistor or dirty plate HE, at a guess. James
  13. G

    Air vent valve

    I don't think the manufacturer will be interested in a leaking aav in the airing cupboard if it isn't part of there appliance. I get this sort of thing all the time, I just had a new boiler fitted and now my immersion has packed up so they call it in trying to get it changed under the boiler...
  14. G

    Your worst unsafe situation.

    I've found loads Gas hob connected with garden hose and jubilee clips, Garden hose suspended from light fittings from a bib tap, to supply gas to two desk mounted bunsen burners. Brand new combi boiler installed in a loft with no flue, and condense running sloped upwards caused the boiler to...
  15. G

    Anyone helpus with Heating prob! why so close to XMAS!!!!!

    It is quite possible the impellor has sheared off the end of the shaft, I find this quite often. Close the two pump valves and undo the four allen bolts holding the pump head to the pump body and take it off and check only takes 5 mins to rule it out. James
  16. G

    boiler

    Most likely cause is a faulty pump, but without proper checks this can't be confirmed. Same problem with the hot water, without further information its hard to say whats wrong. More than likely a divertor fault with the hot water though James
  17. G

    Worcester 28CDi

    From a professionals point of view it would be easier and more cost effective to just change the board if its playing up. Otherwise you run the risk of further call backs James
  18. G

    Connecting up a new gas cooker

    The new cooker won't come with a cooker hose already attached, you will need a corgi to come and attach a new hose and connect, commision and tightness test the installation. Shouldn't cost more than an hours labour plus a cooker hose. James
  19. G

    Yet another boiler recommendation topic

    Broag quinta 45, probably a bit over but scope for extension. James
  20. G

    fan speeds different ?

    Your a clever one aren't you, what you are doing is technically in breach of the gas safety, installation and use regulations. Get someone who knows what they are doing before you hurt yourself or someone else. James