  1. G

    no sound on my laptop

    Hi just wondered if anyone can help me with a problem. I have a Toshiba Equium but the sound has stopped working it worked at one time, and i think i must have muted it at sometime, anyway there is a red cross at the side of the small speaker icon on the bottom toolbar, but when i...
  2. G

    ravenheat rsf 820 /20 pilot

    the pilot is in series with an overheat cut off stat which has prob now gone faulty, as i have said get an r g i to look at it for you, its not a job for the d i y. Thats the only info i can supply you with. At least now you cannot relight it and cause other problems which will...
  3. G

    ravenheat rsf 820 /20 pilot

    Hi it sounds like its a fault with the gas valve its not seating properly when off and allowing a small amount of gas to pass through, or it could be the modureg valve getting a small dc voltage from a faulty board i would turn it off and get an r g i to look at it fast, its ok...
  4. G

    External solid fuel flue

    it may be cheaper to build a brick chimney on the outside as i did once a few years ago all did was to cast a 6" concrete slab into the wall with reinforced wires that was about 5 ft off the floor outside i then used clay 9"liners and toothed the bricks in as i went up and filled around...
  5. G

    RAVENHEAT 820/20T FANNED COMBI

    hi well thats for their own engineers to come out which is most unusual they normally give you at least 3 local to you engineers numbers and never quote money, as that down to the self employed engineer, they must be short of work as they normally only do warrenty work so they must...
  6. G

    RAVENHEAT 820/20T FANNED COMBI

    hi steve its difficult to estimate the cost of a job like that as someone needs to check out why its not bringing the main gas on when calling for water or heating and its a matter of elimination it is not possible to give you the info on what is wrong with it as not a job for d...
  7. G

    ravenheat csi 85 combi

    Hi it does sound like the air pressure switch is not pulling in to operate the ignition, if you say the fan is working the next thing is the air pressure switch should pull in, it can be a blocked ventura or cracked pipes to it It needs checking out properly and so does...
  8. G

    RAVENHEAT 820/20T FANNED COMBI

    hi steve firstly is the pilot on???? and is the fan running at slow speed this need sto run to maintain air in the combustion chamber to keep the pilot alight over a period When you push the gas valve in does the fan run at the fast speed ???? if it does then the ignighter will...
  9. G

    renault traffic motorhome fuel gauge problems

    Hi i wonder if someone could help solve a problem i have with my motor home, the petrol gauge worked ok one day, then i put in £40 of fuel got into the cab and the gauge was not registering and the empty light was on, its never come back to working again, we were on holliday at the...
  10. G

    Branching before a stop cock

    you might have a problem if you decide to have a water meter fitted as you are not allowed to branch off before the main stop tap only thing they can do is to put your meter outside undergrond but a few water companies dont like them that way as they have to send someone to read the...
  11. G

    Capita Gassafe

    I have sent Capita an email last night asking them to tell me as a paying R G I where all the advertising is for the change over. it seems to me all they want to do is take the money,. and leave it to us to tell our customers what is happening , so lets all send them an email...
  12. G

    Central heating - Microbore manifolds

    Hi i have been to loads of micro bore systems installed in the Leicestershire area that have not had mainfolds fitted, they have 22 mm pipe from the boiler then reduced to 15 mm under the floors then to 8 mm under the floors before it goes to the twin entry valves my own house...
  13. G

    Capita Gassafe

    well they did make a big c**k up of the leicester health workers wages ! they had several attempts to get it sorted but found it to difficult, and in the end they were sacked, from what i am reading it does not give me much confidence in their ability to carry the registration out...
  14. G

    Scratched a gas pipe with a saw

    Hi just been reading the post with interest about what to do with the saw cut in the pipe under the floor, just a point that i would like to make that no one has mentioned about, if the pipe is cut through then a tempory bond will need to be put in place, and also the last time i...
  15. G

    Ferroli 77FF: Over-pressurised, tepid DHW now will not start

    hi thanks for the info on your boiler but i do not seem to have any M Is on that model so i cannot see if it has a resetable overheat stat on it i used to have loads of manuals but since getting CDs with all the manuals on i got rid of them as they took up a lot of room in my van...
  16. G

    Ferroli 77FF: Over-pressurised, tepid DHW now will not start

    Hi perhaps you could give more details on the boiler IE G C number which is on the data plate as i have looked at the boiler info that i have got on my laptop and it does not list a 77ff as a combi and it only lists up to a 60ff and they are all cast iron boilers back to your...
  17. G

    enable my wiffi encription security

    hi many thanks for all your input i am now protected against any of my neighbors using my broadband, just shows how easy it is when you know how , i am a big believer in every man to his job i deal with gas boiler repairs etc and they can be a bit complicated for people if...
  18. G

    enable my wiffi encription security

    Hi i am in need of some help please i have a netgear wireless router on sky broadband but its not secure my son came to visit and he was able to log on to my broadband and use it what i want to know is how do i get into the modem settings to be able to set up the w p a as i...
  19. G

    Ravenheat 84ET Water leak from top of boiler (red cap)

    Hi what is leaking is the auto air vent and it needs removing and either stripping down and cleaning out or just replace it the cap on the top has to be left loose or any air that gets trapped in the top of the boiler cannot get out The problem is it is not a job that you can do...
  20. G

    Leaky radiator tail

    yes use hemp and hawk white sealing compound used to be boss white, never had any problems with leaks when using it , so give it a go mick
Back