Search results

  1. B

    I'm Looking for energy saving advice ...

    Hi oilman They are white deal, I think, and they are starting to rot. I spent the first 2/3 weeks of the summer repairing and painting them. My plan is to replace them in 4/6 years time. Do you mean that by turning off the radiator valves, that I can disconnect the radiator (with...
  2. B

    Terminating Light switch Earth

    I didn't know that - ta!
  3. B

    Terminating Light switch Earth

    Qedelec - do you mean a choc block, and just leave it loose in inside the dry lining box?
  4. B

    I'm Looking for energy saving advice ...

    Many thanks for all of your replies. I will definitely look into upgrading the loft insulation and immersion lagging jacket. The house was built in the early 1970s so would it be save to assume that it has cavity wall insulation already in place? Double glazing is part of the long term...
  5. B

    I'm Looking for energy saving advice ...

    Hi Guys, We are running a kerosene burner, probably very inefficiently, and with the cost of oil rising it's time to think seriously about modernizing the system. I know absolutely nothing about heating systems so I'll start by outlining what we have: * Bungalow *...
  6. B

    Can anyone identify this device?

    So it's like a relay then? This would kind of make sense in relation to the roof heating. The heating consists of conductive sheets laminated between clear plastic in the attic. Each room in the house has it's own thermostat mounted on the walls. The reason i'm asking is that I have booked...
  7. B

    Can anyone identify this device?

    I was wondering if anyone can identify what the device is in the bottom left hand side of attached image? - I recognize the cobwebs mind you! We have roof heating installed since the 1970s, which was made by Flexel. Could this be a transformer for the heating? Thanks, Bothy
  8. B

    just a quick question

    The sockets below the counter are not powered directly off the ring. Wire the input side of the swiched FCU directly from the mains ring and then wire the output side of the FCU to the appliance socket. This allows the whole socket to be isolated by flicking a switch above the counter.
  9. B

    2 Way Dimmer Problem

    The metal mounting box may have a small brass terminal on it - if so connect the earth wire to it.
  10. B

    2 Way Dimmer Problem

    What way was the old switch wired up? Also is the switch metal or plastic (and the same with the mounting box)?
  11. B

    indesit 3000w dishwasher

    I have mislaid the instruction manual for my indesit 3000w and can't find one on the net. Has anyone information on cycles 5 and 6 (also marked 's' and 'Rapid') please? Do I use soap with them?, ... Thanks, Bothy
  12. B

    20mm round conduit: How many cables?

    Thanks breezer -I've just discovered that the three cables wouldn't get past a male conduit adapter anyway.
  13. B

    20mm round conduit: How many cables?

    I want to put three cables in 20 mm round conduit. Two of them are 2.5 T&E, and the other is 1.5 T&E. Needless to mention, the space is very tight. The guy in my local electrical supply shop said that I would be able to do this if the cables are straight, and taped at regular intervals. I...
  14. B

    Difficult electrical questions (well for me, anyway:-)

    Root-mean-square can be calculated as follows: 1) Square all the values 2) Get the average of the squares 3) Get the square root of the average The above works fine if you have a number of discrete values. To apply this to a sine wave, such as AC voltage you can integrate as...
  15. B

    Spur point

    Thank you spark! 20A, 2.5 T&E. Room area approx 22m²
  16. B

    light rose - 2 cables in

    Assuming that he wasn't using a Fluke, or equivilant, ... measuring resistance across a 230V live circuit would cause plenty of smoke & bang!
  17. B

    Spur point

    Hi Guys, I want to add a spur from a radial circuit to feed a double socket. The most convenient place to take this spur happens to be more or less beside the CU. Can I make the spur point inside the CU at the mcb terminal, or would it be better to add a 30A junction box on to the...
  18. B

    sending files

    Recent versions of outlook automatically block exes and other types of attachments (screen savers happen to be one of these). The blocking seems to happen at the receiving end so the sender will not be even aware that the reciepient didn't get the attachment. You need to play with the...
  19. B

    ZoneAlarm Pro 6

    pipme, I am a registered user. I got an autoupdate this morning - the first one afaik for version 6. There is a new defence level called SmartDefense which I haven't really studied yet. There is also a built in anti-spyware scanner. I haven't had any problems today so far.
  20. B

    Rewiring of garage circut

    crafty1289 - here is the image you were looking for.
Back