Search results

  1. N

    Adding a room stat

    Thank you for your excellent advice. I will go down the Honeywell route now on your recommendation. My last question is that some of the replies suggested going wireless. The CM907 though is wired so the best/easiest I could do with that is get it into the hall. If I really need it in the...
  2. N

    shower is leaking!

    I have a nasty feeling that there might be a piece of the screen missing in addition to the seal (which is definately missing!). I am pretty sure I have the same screen at home, but in white, and stuck/bonded on the top of the bath should be a rail. The bit on the end of the screen locks in...
  3. N

    Collapsed Wall Around Window Helpppppp !!!!

    Top tip - don't remove the windowsill unless you really have to as this sort of thing nearly always happens!! Seriously though if it is only the bricks that are missing from the photo that are loose then nothing to worry about, and a good/simple little DIY repair. If the bricks that came off...
  4. N

    Adding a room stat

    No - it was for an RF unit as far as I recall. My wife was given the quote verbally when the boiler was being serviced but I thought it sounded very expensive, hence doing it myself.
  5. N

    Adding a room stat

    Thanks for the response - it is much appreciated and sorry for the delay in responding but I work away a lot. Anyway in answer to your questions: I don't think I am explaining myself properly! The LP111 only controls the gold pump, and can be set to come and and off at different times to...
  6. N

    Shower Leak

    No probs - glad I could be of some help!!
  7. N

    Shower Leak

    Duplicate post
  8. N

    Shower Leak

    Having now studied the photos again it look like you dont have a basket fitted (unless that is it stood in the tray in the bottom picture?), either way you can see the castellations I am talking about, and that is what the waste pipe 'key' needs to fit into. Alternatively if the fitting is...
  9. N

    Shower Leak

    I am only an amateur DIY person I admit but you clearly have a problem! It may well be that whoever installed it has got the sealing washer in the wrong place - but hard to tell without dismantling it. The problem you have is that the top of the chrome fitting should be flush with the top of...
  10. N

    Lovely old white painted woodgreenhouse in very sorry state

    Hi - it sounds nice but I don't think there is a cheap way out of restoring what you have - especially if you want to preserve it and make it look good. In reality you need to strip the greenhouse down, firstly removing all the putty and glass sheets. If some break don't worry as greenhouse...
  11. N

    Adding a room stat

    Hi - thanks for the response. Just to clarify the LP722 controls the central heating and the hot water, the LP111 just controls the gold pump that supplies pumped hot water to all the taps (upstairs and downstairs). I can quite easily put the room stat in the hall (as we have an integral...
  12. N

    Adding a room stat

    Hi all - looking for some guidance and advice please. I live in a large detached property built in 2000 to the then current regs by a very reputable local builder. We have lived here for 4 years however I noticed that I dont have a room stat fitted in the house, just TRVs throughout. This...
  13. N

    Yet another shed wiring question/advice needed

    I would do - if he were here!! But he isn't back until 6th May by which time the trench will have been backfilled with the cable, or ducting, in it. I appreciate your point about the BS EN standards but do they apply if it is SWA cable inside which I could bury iaw the regs without ducting in...
  14. N

    Yet another shed wiring question/advice needed

    Point taken - hadn't thought about ducting. I have loads of 2" waste pipe in the garage. Do you think that would be ok with a draw rope as there wont be any bends - just a straight run with a pit at either end for access until the cable is in? Also do I still need to cover it with tape as it...
  15. N

    Yet another shed wiring question/advice needed

    Hi All Sorry to ask this as I know there are many threads on similar subjects but I thought it best to ask a specific question! Anyway I am about to run power to my new summerhouse in the garden in advance of the electrician finishing the job off - and the following is a summary of my issue...
  16. N

    Glowworm 30Si Problem

    HELP !!! I have a problem with the above boiler that is running me around in circles, and costing me a fortune in callouts, and wondered if anyone has experience of the same problem. The boiler was installed in 2004 by a CORGI engineer and in the main has worked fine ever since. I did have...
Back
Top