  1. N

    worcester 24i

    The 24i dosen't have a plate h/ex. The only other reason could be the filling loop letting by as has been said. Not being confused with the Junior is it?
  2. N

    water heater

    There's an o ring where the spindle passes through. Change the o ring and make sure the spindles not dirty/damaged.
  3. N

    New consumer unit

    I've been informed by an electrican that if I extend or add a circuit to my existing ring main that I need to upgrade my consumer unit to RCD. It currently has a Memera MCB unit(about 20 yrs old). Still has a couple of blank outlets as well. Is that right?
  4. N

    Aspect magazine

    I thought they'd stopped producing it.
  5. N

    Baxi Combi 80e "Hot then Cold" Fault on Fan or Flu

    Sounds like a sensor fault now.
  6. N

    Vokera Flowmatic 20/80 rs no hot water

    Remove the switch from the pump ch/pump flow switch and push in and out with pliers (being careful not to scratch it). The spindles can get dirty and not move smoothly. You might also find the pump might be weak.
  7. N

    worcester bosch 24 si mk2

    Agreed. There are 2 pcbs available for this model so make sure you get the serial number befor ordering.
  8. N

    Baxi Combi 80e "Hot then Cold" Fault on Fan or Flu

    Had the same problem this week on a Baxi 105e. It was the pcb. Worked ok till it reached temperature and then when it tried to relight the power to the fan was intermittent and the flue/fan light started to flash.
  9. N

    Baxi Genises 80 Combi ramdomly cuts out

    Same boiler as a Britony Combi. As said, sensor/flow switch regular faults on these but does sound like a pcb problem. But it is very intermittent so you might have to live with it :)
  10. N

    Vaillant EcoTec Pro F75 fault

    There is dirt in the water pressure sensor. It needs taking out and cleaning. A common fault on this model. Get yourself a gas engineer.
  11. N

    incomming mains pressure

    If they've connected it to the same water main in the road it should still be 5 bar. Working pressure or standing pressure?
  12. N

    British Gas and personal Gas safe registration

    Any guys with dual registration left of their own accord round my way. Not heard of anyone being sacked.
  13. N

    Potterton MF80 boiler over heat/lock out

    A faulty PCB on this appliance can cause overheating. They just fail to switch off.
  14. N

    Sealed system expansion vessel question(s)

    Because sealed systems require an overheat stat. Don't think Mk2 Flamingos had them.
  15. N

    Sealed system expansion vessel question(s)

    And don't forget the overheat stat!!!
  16. N

    Kingfisher mf boils now and again

    Had this problem with a few mf's. Normally the pcb.
  17. N

    Bg employees or ex employees

    A lot further south than you. Why has it been cancelled? Much more expensive to get contractors in.
  18. N

    Bg employees or ex employees

    Not round my way. Were 10000 behind :shock: , unlikely to be cancelled.