Search results

  1. X

    Pumped shower problem

    I don't think I've tried that one, if you start the shower without the pump, you get a drip, I'm sure nothing happens if you switch the pump on. I did flush through the feed pipes after install into a bucket and thinking about it the flow was very good?! Latest development is if you wobble...
  2. X

    Pumped shower problem

    Thanks for reply. Pipes are running along loft floor, so deffo all well below tank. There could be air, but when it runs, it's runs fine. There is a secondary feed off the hot tank, which I used, I have heard some rumours that this isn't a good idea, I can't work out why tho. The pump does...
  3. X

    Pumped shower problem

    hi all, I hope someone could help me with this as it's got me stumped and the only thing left is to try random things to try and sort it, which I don't want to to...customers getting annoyed too. House has had new bathroom fitted by us, old bathroom had gravity shower via a (aqualisa, I...
  4. X

    The plug of a dishwasher starts to melt !

    I was thinking that at the time..... Could I just slide it back in and it would plug itself back in..! I didn't...
  5. X

    The plug of a dishwasher starts to melt !

    That reminds me, I've pulled a dishwasher out before and it's pulled the plug out the socket where it was stuck to the back of the dish washer!
  6. X

    22mm Copper Pipe through joists

    Spade bit or I use auger bits. Can't remember the size, 25mm rings a bell, you will need to measure the od of the pipe.
  7. X

    22mm Copper Pipe through joists

    Yeah sounds fine, just use a sharp bit. You will have to make sure the holes are lined up and straight, 22 copper is very unforgiving. Never use copper for hidden anymore, sad but true. Easier quicker.
  8. X

    How to mitre porcelain tiles

    I'd go with your last statement.. The tiles will chip on the edges with a wet cut.
  9. X

    Major heating issue please help..

    I'm no boiler expert but I'm sure the boiler should kick in before 27o. Anyway... You must have a blockage...next step is to take a cold rad off and see of you can get a flow from the valves.
  10. X

    Major heating issue please help..

    So what happens when you do this?
  11. X

    Major heating issue please help..

    I agree with this... How can the system have been correctly balanced if half the rads aren't working...?!
  12. X

    Outdoor tile adhesive??

    Clear silicone
  13. X

    Outside power

    I'm forgetting myself because technically it will be Spurs off a spur. So fcu it is then.
  14. X

    Outside power

    Isn't there something in the regs about a max 2kw off a spur for a fixed applicance, summer houses falling under this?
  15. X

    Outside power

    hi all, Outside summer house for small gym. Couple sockets, light. Need power, 40/50m approx cable run from back of socket, 100m to cu. 1st option is fcu off back of socket via armoured but limited to 13a, borderline acceptable. What's the probable max load you could run off back of socket...
  16. X

    The Perfect Grouting

    Time, care and experience.
  17. X

    Bathroom refurb - wet underfloor heating

    Whole house is zoned, with all rooms with own stats. Whole upstairs must be done the same way. Customers not complaining but hasn't been there long.(months)
  18. X

    Plasterboard onto plasterboard?

    Your old stairs have beading, your new does not. If you got some wide beading, would this not achieve the same thing?
  19. X

    undoing speedfit

    Plastic or copper pipe? Because I've seen a 'ring' of crud on the end of copper pipe on push fits, which could make it difficult to remove.
  20. X

    Bathroom refurb - wet underfloor heating

    Image by xr4x4 posted 4 Nov 2015 at 9:07 PM Grey pipe.