Search results

  1. B

    Y Plan

    you still listening to noah w plan!!!!!!!!! :lol: :lol: :wink:
  2. B

    Gas supply pipe...correct size or not

    5.4m3/hr ?what about the boiler and their own kitchen plus the dfe in the bar[if their is one]
  3. B

    Gas supply pipe...correct size or not

    There is 3 gas appliances going into the commercial kitchen: Falcon Dominator 6 burner range.....5.8kw 20.000btu/hr Falcon Chieftan single bullseye range.....20kw 68.000btu/hr Falcon Dominator twin pan fryer....40kw 136.000btu/hr Hope this helps Rich 15mm :lol: :lol: :lol...
  4. B

    cutting a plastic bath panel

    little dremel with the right cutter,masking tape gives a good guide if the dremel veers off line a medium file or rasp soon sorts it out.cut the panel outside or the bits go everywhere :oops:
  5. B

    29 mb when doing tightmess test

    just a couple of points 29mb is not unusual in belfast we have low pressure and medium pressure your test depends on type of supply low pressure is 20mb medium pressure is 16 let by 10 let by and test at 20mb,two let by tests on medium ecv and governor then tightness at 20mb,hope this...
  6. B

    3/4 npt

    you put the left die in you take the right die out you do the okey cokey and you shake it all about, thats what the npt is all about whoaaaaaaaa :lol:
  7. B

    Loud oscillations from Ariston combi boiler - please help

    mts wrote 1. The manual is wrong, the correct air/gas ratio figures are 8.7% as suggested here. :lol: 3. The manual is also wrong in saying the minimum gas pressure is 17mbar, it should be 20mbar, however the techsupport person said I would get away with 19mbar without problems. he...
  8. B

    Loud oscillations from Ariston combi boiler - please help

    ariston have changed a few things with this model positioning of condense trap being one and the manual vent on the lhs of the heat ex early ones were upright new ones tend to drip on the stat as they face you :roll: and the early ones tend to split heat ex on the lhs in the middle of the...
  9. B

    Loud oscillations from Ariston combi boiler - please help

    co2 setting min %vol 8.7+/-0.2 after 4mins of operation working pressure 20mb
  10. B

    Loud oscillations from Ariston combi boiler - please help

    Well the manual says 17mb is sufficient.. ???? so why do you say 20? because i am familar with this boiler and competent thats why :lol: your min co2 is correct 8.7+/-0.2 adjust max down to 8.7+/-0.2,you will need a digital u gauge as well to complete the commisioning.
  11. B

    Loud oscillations from Ariston combi boiler - please help

    pays to use a competent person :lol: by the way pumps sticking on these is common nothing to do with your problem. to help you you MUST have a min of 20mb at the boiler not at the isolation valve.
  12. B

    Loud oscillations from Ariston combi boiler - please help

    the manual for the aco is very comprehensive and will give you all the info you req to comission it, it must have 20mb min working pressure your readings for co2 are incorrect no digital u gauge?
  13. B

    BG strike again.

    agile wrote But my CORGI inspector disagreed and wanted BOTH sides sealed even though I had the rubber gasket on the inside. He slightly backed off when I disagreed with him and told him it was NOT a manufacturer's requirement but still insisted that it was good practice. have to agree...
  14. B

    Project AGA Rayburn Heating

    have a look at www.range -cylinders.co.uk the flowmax is the type 8) www dot range-cylinders dot co dot uk :roll:
  15. B

    How do you get started if you'e new to the uk...

    then why do i attend so many breakdowns where the cust has forgot who done the install,no paperwork,no benchmark?and why am i charged for the right to work and when i have informed corgi of unregistered installations/installers dam all is done about it.wake up and look around you harrogategas...
  16. B

    How do you get started if you'e new to the uk...

    harrogategas wrote If he does not get Corgi registered then he will be breaking the law working on gas and get a severe penalty and/or prison for doing so. :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: utter testicles,how many unregistered...
  17. B

    Changing Propane over to Oil, Condensing outlet problem!

    mike2007wrote Flues..everything's about flue regs! because they are important and concern the SAFE OPERATION of the appliance.
  18. B

    Who manufactures the best combi?

    whilst i appreciate your comments simmond not too many people have viessman products i think you will find most are more mainstream makers and have 50/75 litres again this is an assumption based on experience.
  19. B

    Who manufactures the best combi?

    no i have not checked,but made an assumption based on experience with storage combis.and yes i had read chrisr post.
  20. B

    Who manufactures the best combi?

    flow rates drop off once the store is depleted so you only get 10/12 litres rather than the 18/20 the manufacturers like to shout about :shock: