Search results

  1. Screenshot 2023-04-20 at 13.31.47.png

    Screenshot 2023-04-20 at 13.31.47.png

    UFH schematic for electronic mixing valve with VR71
  2. Screenshot 2023-04-19 at 17.08.19.png

    Screenshot 2023-04-19 at 17.08.19.png

  3. Heating system

    Heating system

  4. 20230418_204704.jpg

    20230418_204704.jpg

    Current heating setup
  5. 0ldskoolskater

    Zone valves - what does PL on schematics mean??

    Just realised and edited my post as you'd replied - thanks! From where should it be picked up from as per best practise? Can you nick it from the supply live?
  6. 0ldskoolskater

    Zone valves - what does PL on schematics mean??

    Evening, Regarding zone valves and end switches - what does the 'PL' bit of PL 230 v on the drawing mean? It appears to be the supply for the switch on the zone valve, so is it 'permanent live' ? And from where should it be sourced as a best practise? cheers
  7. 0ldskoolskater

    Vaillant VR71 demand input voltage

    Calling all VR71 owners! What voltage is present at the external demand input S6/S7/S8 terminals on the VR71? I'd like to add a 3rd party UFH system which uses these terminals to call for heat, so want to make sure that by connecting a UFH wiring centre which has a volt-free output, that this...
  8. 0ldskoolskater

    24v eBus main CH system - how to add 240v UFH circuit?

    Thanks Chris It's a Roth Basicline 230v with the following: - Roth actuator 230V N/C part no. 7466275433 - Roth Basicline T digital thermostat part no. 135007436 - Roth connection mod AM10 Basicline 230V part no. 1135007709 - Roth shunt 3 way part no. 7466210218 I'd like to connect the above...
  9. 0ldskoolskater

    24v eBus main CH system - how to add 240v UFH circuit?

    Hey All, I have a Vaillant main CH system running control via eBus at 24v - my builder has provided a 240v control UFH system, and I can't think of a way to connect this into the main CH system. Do I have any options to make this work apart from returning the 240v UFH controls and getting 24v...
  10. 0ldskoolskater

    Upgrading/extending Vaillant vSmart system to multi-zone sensoCOMFORT

    Ah, might've found the diagrams - I was searching for wiring rather than schematics.. https://www.vaillant.co.uk/downloads/product-manuals/sensocomfort-2/sensocomfort-boiler-schematics-instn-guide-v3-2600079.pdf
  11. 0ldskoolskater

    Upgrading/extending Vaillant vSmart system to multi-zone sensoCOMFORT

    Hi folks, We're extending the house at present and I'd like to extend my current Vaillant home solution to accommodate 2 new UFH zones into the Vaillant system. The house is currently a basic 1 CH zone with manual TRVs and 1 DHW zone connected as S-plan. At present the following central...
  12. 0ldskoolskater

    Filling tap holes in cast iron bath

    Would rather have the appearance of the holes never being there. Blanks will do the job but it needs to be aesthetically pleasing also if at all possible. Wondering if this might do the job - might be an easier onsite task than welding...
  13. 0ldskoolskater

    Filling tap holes in cast iron bath

    I'd like to fill the tap holes in our cast iron bath but not sure if it's possible? My first thoughts were welding fillers in then re-enamelling the batch, but then thought about the liquid metal stuff I've used in the past instead of welding. Any thoughts on what the best thing to do might be...
  14. 0ldskoolskater

    Connecting Owl Intuition cw to Vaillant EcoTec boiler

    Hi Degsy41, What did you do in the end about this? I am in the same position albeit with a VRC Four thirty and it would be helpful to know what you decided to do. Cheers Oldskoolskater
Back