Id recomend bottom tappings either side. top and bottom ethier end can cause a cool bottom corner below the top entry valve if flow is inadequate and also leaves a vunerable pipe on top feed
Hi my main tv where i have sky hd box cant get a freeview signal . Got 6 orther tv,s through sky booster and they all tune in fine, main tv has just a hdmi lead from sky box , Do i need a coax into this tv and if so from where, Thanks
thanks for your replies . Probably sell as is on ebay . hes bought a new identical for £279 from argos . Insurance has a 100 excess and i have a 30% discount so not worth claiming, Thanks for your replies
Fitted mira and JT trays among others , Would say the mira is the better quality of the two. once had a bent 1200 x 800 JT 40, they replaced it but was a hassle . they should always be stored flat
the back pressure is making the flow switch in the pump move move briefly making pump start. must be more sensitve than last pump, no easy fix. a direct hot tapping out of cylinder may help but easiest option is to fit a pull switch in bathroom to isolate pump power when not in use, it is a...
Iv taken the vent off waste pipes under bathroom floor and up a cupboard into attic and through gable or roof before now in waste pipe just to get a vent to outside , If you dont shower wastes often suffer and let smells out
It can be boxed in but a small vent in box is best . on top where not seen is fine so ii can be pulled in if required, vent is normal 110mm like stack but reduced down to 50mm waste pipe will do
The durgo is fitted which changes the soil vent stack into a stub stack, the durgo is only designed for internal instalation and will let air into to stack to prevent suction ( induced syphonage) sucking water out of any trap connected to it, the open vent to outside air will release any...
Thanks for reply. Got 2 seperate manifolds fed via worcester heat pump, fuse blew on upstairs manifold board. replaced fuse and blew instantly, checked wiring in zone valve & removed pump & vonevalve wires = fuse ok. reconnect zonevalve & fuse fine, then pump and still fine so never found a...
Thanks for reply. Got 2 seperate manifolds fed via worcester heat pump, fuse blew on upstairs manifold board. replaced fuse and blew instantly, checked wiring in zone valve & removed pump & vonevalve wires = fuse ok. reconnect zonevalve & fuse fine, then pump and still fine so never found a...
I'd try the motor 1st If you isolate power & remove syncron off the plate if the motor is jammed it should free the micro switch, New motor is a cheaper fix. worth checking out 1st
Boiler fires on dhw demand and reachs 78 degrees on display and shuts down then fires again when drops a few degrees then shuts down. No heat at all on flow out of boiler so diveter ok but only luke warm water and soft water area? Is plate exchager sludged and which cleaner best if removed or...