Search results

  1. J

    Modification to Existing Ring 2 Parts

    Hi, id like to get your thoughts on the following: I was asked to extend a downstairs ring today by adding a couple of sockets in a dining room, no problems breaking into the ring and adding the required sockets, however, I noticed that the conservatory had 4 dbl sockets, FCU for Air con (3KW)...
  2. J

    Switch Options for Low Voltage Lights

    I was thinking of a 2 module grid, both with fused spurs, 1 for the Hood, the second to power the lights, you could then add a switch down the line in a more suitable position. but as B-A-S suggested, if you were to make it a 4 way grid you could switch both fused spurs, (so as to isolate them)...
  3. J

    Switch Options for Low Voltage Lights

    Hi, you might want to look at grid switches, you can get a fused unit like this -> http://www.tlc-direct.co.uk/Products/MKK4890.html, then i don't see why you cannot switch the live in a standard switch - maybe somebody else can confirm this is ok:?:
  4. J

    Cable Pulling

    Like this Thread :?: :?: It's sometimes good take your own advise lol :shock:
  5. J

    Cable Pulling

    Saw and tried these , I think there great (£17), note the flexible nylon bit is not very strong. i.e. it broke the 1st time i used it, but the rods and the brass hook and eye do a good job. :)
  6. J

    NICEIC Domestic Installers Scheme Questions (Part P)

    I Spoke to a nice at lady at niceic who told me she would send me all the relevant info - when it came it was the application from!! - I want to do it, but, as per the post I want as much info before I cough up the £325 plus vat, at which point it's too late (non-refundable fee) and or £175 +...
  7. J

    vintage light switch reused?

    Doesn't the Oak class as a combustible material? - and thus not conform to the Regs :?:
  8. J

    NICEIC Domestic Installers Scheme Questions (Part P)

    Hi All, It looks like part P is coming, and the above is essential for me to continue, I currently refurbish houses and Re-wire / modify where necessary, I have my 16th edition and Testing inspection qualifications however the point of my life story is - I don't get loads of practice testing...
  9. J

    Replacing a Consumer Unit - Cable too Short

    Thanks for the info - :) , just curious - is this method mentioned in the regs / on-site guide been looking for it and could'nt find it??
  10. J

    Replacing a Consumer Unit - Cable too Short

    Hi - Can anybody give me some advice please? - I want to Change my CU to a Split load RCD unit as the current CU is only 4 way - and I want to add a Shower Circuit. I know that the cables inside the current CU will be too short - what is an acceptable way to increase the Length of the...
Back