Search results

  1. J

    Loss of pressure - where's the leak??

    AAV maybe?... iv found them to leaks on 24/28i....
  2. J

    single panel double convector

    i asked a coupla work colleges who basically said the same thing... but im sure iv seen them on my travels... maybe they were low surface temp rads... but anyway i went for a double panel single convector in the end... thanks for the replies guys!
  3. J

    single panel double convector

    hi... does anyone know where i can get a single panel double convector radiator from??.. about 1000 x 600 - 1200 x 600... im havin a bit of trouble locating one online... Harrow area... cheers..
  4. J

    worcester 240

    Yo all!! im having a bit of trouble with a worcester 240... i understand that the boiler is a little bit dated.. the old pcb on the boiler was malfunctioning so i put a new main pcb in... and whats happening is the relay switch on the pcb keep clicking on and off... the boiler is working for...
  5. J

    Multimeters

    thank for the advice guys... but are there any brands that u can recommend.... i have seen a Di-LOG DL9206 for bout £40 which seemed ok.. but the guy i was with said i should shop around a bit.. he hand really heard of the brand... also does anyone know websites where i can purchase this kinda...
  6. J

    Multimeters

    Hello... can anyone recommend a decent multimeter.. im in the heating trade.. still a little bit fresh to it... and require a multimeter to test voltage and resistance... maybe temp also... someone recommended a fluke 116... it looks ideal.. but i didnt wana spend that much seen as though...
  7. J

    ways to increase pressure...

    hello... I have a conventional system... with a cold water cistern in the loft and a hot water cylinder in the airing cuboard... i wanted to know of anyways to increase the pressure to my taps... how does the flow rate effect this?.. i know there are pumps available for showers, can these...
  8. J

    Disabled facilities

    HI all.. I know someone who has a brought a restaurant and has to bring it up to scratch... it is required to have a disabled toliet amoung other things... what are the guidelines regarding disabled toilet/wc facilities??... and where can he purchase these disable friendly items?.... based in...
  9. J

    shower mixer

    cheers mate... il crack on then!
  10. J

    shower mixer

    I have a question for you guys... im doing up my bathroom... new suite and want to fit a grohe thermostatic shower mixer... i have main pressure to the bathroom (combi boiler)... can i take the supply for hot and cold by teeing off from the supply to the bath taps?.. or do i need a seprate...
  11. J

    Signs of spilling

    ^^ yeh i wouldnt put it past them... I might take off the case and have a closer look... Any suggestions on a boiler when we do change... we'l keep the system combi... 8 rads in the house... bout 28 kw we'l be lookin at...
  12. J

    Signs of spilling

    Hi all... my first post so il make it a good one.. Heres the situation.. A my aunt has an old valiant balanced flue combi boiler.. im not sure of the model... but i know that its about 20 - 25 years old... maybe more... it is working fine... however i have noticed some staining marks around...