  1. T

    Multimeter

    Maybe I picked the wrong smile then but was being sarcastic here.........not that I am rolling in it like :cry:
  2. T

    CH problem onWorcerter 28i junior

    Yep checked the modulation, hitting min and max values, undergoes min rate then ramps up in the required time Agile
  3. T

    A quick Corgi (not the dog) question.

    Its all semantics- you get told there and then whether u have passed- the fact corgi don't officially know for so many days ? what does it matter
  4. T

    A quick Corgi (not the dog) question.

    Couldn't put it better meself :)
  5. T

    Multimeter

    I can't afford £24.99 :shock:
  6. T

    Multimeter

    Basically testing on boilers, any1 got any recommendations on where to source meters that have been recommended?
  7. T

    A quick Corgi (not the dog) question.

    No they don't , they can work under the companies corgi
  8. T

    A quick Corgi (not the dog) question.

    You receive the results of your ACS as soon as you have done them .
  9. T

    CH problem onWorcerter 28i junior

    Bump- opinions anyone? :)
  10. T

    CH problem onWorcerter 28i junior

    Well I took the I took the heads of 2 trvs in the lounge and dinng room but boiler still kettling and o/h stat looking boiler out. This is not a hard water area, no scale on kettle at all so that shouldn't be a problem on a HX in a 3 year old boiler. Customer says the system was cleaned...
  11. T

    Multimeter

    By abuse I didn't mean chucking it about Softus but obviously a meter that is used on the job and carried in your van/sack is going to get more knocks than one that is kept at home on the shelf for work in a lab type environment.
  12. T

    Multimeter

    MY multimeter has just gone T**s up. Anybody recommend a decent one that is rugged enough to stand up to some abuse?
  13. T

    Boiler Change

    I don't know about the education I just received off you but over here there ain't much difference in labour costs on installing anything from a 20kW to 42kW combi- we were talking domestic boilers - we do not install comercial sized boilers in domestic houses ! Something to do with not wasting...
  14. T

    CH problem onWorcerter 28i junior

    Thanks for your reply gasguru, understand your reasoning re the size of the bathroom radiator and will check what effect having trv on lfully open on the lounge rad has but this system has apparently worked OK for 3 years so must be something new causing overheating and kettling in HX, either...
  15. T

    CH problem onWorcerter 28i junior

    Thanks for the replies. There are only 5 rads on this system, the one in the bathroom doesn't have any trv. Looking at the manual I can't see any integral bypass, there is definately no bypass been installed under the boiler. It has run ok for 3 years(since it was fitted apparently...
  16. T

    CH problem onWorcerter 28i junior

    This is not a condensing junior. It was installed sept 04. The HW works fine but on the CH side when a demand is created it takes about 10 to 12 mins to get up to temp( all rads get hot, actually only 5 rads) then kettling occurs in the ~HX the O/H stat kicks in and shuts the gas valve and the...
  17. T

    Boiler Change

    The boiler was a worcester 37kw cdi - done it now , nice easy straightforward job. Don't why the rating of the boiler should affect your price in the US though?