Search results

  1. V

    Domestic Installer Scheme

    Can anyone point me in the correct direction please.Received application form from NICEIC.I understand that i have to nominate two sites for assessment,one being notifiable work and the other not.I intend to use my own property for the notifiable work as in a new consumer unit and the other a...
  2. V

    toilet flushing leak

    when i flush my toilet i get water leaking between the cistern and where it joins the pan,is there a rubber seal that would need replacig in there-toilet approx 20 years old ?
  3. V

    Like for like replacement

    well i'm none the wiser then :(
  4. V

    Like for like replacement

    Living room, but also fitted mains voltage in bathroom pre 2000.
  5. V

    Like for like replacement

    When replacing a light fitting with mains or low voltage down-lighters,is this notifiable or not ?
  6. V

    Low voltage lighting

    When wiring low voltage lighting,is there anything in the regs that say you cannot use cable flex for the permanent wiring of these fittings ?[/b]
  7. V

    low voltage cable selection

    ok thx for the info,much appreciated thx :)
  8. V

    low voltage cable selection

    ok i follow that thx , if each light had its own dedicated cable directly going back to the transformer (transformer has provision for 3 cables on 12v side) would the same principle apply?
  9. V

    low voltage cable selection

    I'm planning on installing 6 low voltage down-lighters,each lamp is 20w.Supply of lamps will be coming from two 20-60 transformers-each transformer controling 3 lights.Cable i plan on using from transformer to each light (which in length is approx 2 metres max to furthest point) via a junction...
  10. V

    junction box's for low voltage

    You're right about the JB's from b+q ! :lol:
  11. V

    junction box's for low voltage

    35-105va transformer suppling 4 20 w lights
  12. V

    junction box's for low voltage

    When installing low voltage downlighters , what is ok to use for junction box's on the 12v side of transformer -5amp ok ?
  13. V

    fuse protection on radial

    sorry i mean 13a fcu, so you are saying use 4-6mm cable from cu to fcu ?
  14. V

    fuse protection on radial

    i understand that if i wanted to create a new radial circuit off a 30a fuse which is already supplying a ring main,the new sockets (3) on the radial have to be protected by a 20a fcu.What will protect the length of cable (2.5) from the cu to the fcu before it gets there ? does it need any ?
  15. V

    radial circuit

    Ring main is on a 30a cartridge fuse,cable is going to be run in loft of garage then down inside partition of walls to sockets.Are you saying put a fcu with neon locater in wall for the cable then to sockets?
  16. V

    radial circuit

    I'm not with you on that,2.5 cable direct from c u to first socket then to next and then terminating at the 3rd. fused spur ?
  17. V

    radial circuit

    On a ring main protected bya 30a fuse,would it be possible to run a radial circuit direct from the consumer unit off the same fuse supplying 3 double sockets?would it overload the fuse ?
  18. V

    fire hoods

    A friend is having his conservatory plasterboarded with a false ceiling.He has asked me to install down-lighters in the new ceiling,will i need to install fire hoods above the down-lighters being there is no room above the conservatory
  19. V

    lights fusing

    i have a light in my kitchen with 4 50w bulbs,problem is every now and again the bulbs start to blow,sometimes quite soon and sometimes after a lenghthy time-any ideas ?