  1. T

    vaillant TURBOmax VUW shuts down

    erm out a new gas valve innit :wink:
  2. T

    Biasi heating a koi tank

    all i know is theres 2 22mm JG ppes to connect to his combi. looks like yours is a system boiler
  3. T

    vaillant TURBOmax VUW shuts down

    by calling him did this mean he came out and inspected the boiler?
  4. T

    valiant tubo max heat exchanger

    theres a DS12 as well im sure dunno how powerful this is like,, they all must be descalers DS=descale :idea: :lol: :lol:
  5. T

    Biasi heating a koi tank

    similar set up with pipework etc john, that tank looks beautiful by the way :wink:
  6. T

    Biasi heating a koi tank

    im only the man to put the boiler in,, i know the guy has spent thousands on filtration systems etc and he has some sort of room/temp stat to wire into combi. he only wants it to keep it too 11' for the spawning or something god only knows guys. BTW koi keeper in newcastle i know a guy who...
  7. T

    Baxi 80e Fan / Flue Fault

    what does the boiler do, does it try to fire, does the fan cycle on and off.. i had one of these before and changed allsorts pcb, aps, fans etc and it was the restrictor ring in the flue... how do they work for yrs then start doing that eh :?:
  8. T

    vaillant TURBOmax VUW shuts down

    does the fan run? does the pump run? does the pump proving switch lift at the rear of the pump? is the PPO pipe blocked? normally if gas valve goes altogether on one of these babies the fused spur usually just eats the fuses
  9. T

    Biasi heating a koi tank

    im sure my friend/colleague/customer mentioned 8' or 11' as the required temperature for the koi to spawn. im doing this as a cash job for a mate im taking no responsibility for the JG flow and returns he's already installed i will be installing/testing and commisioning the combi to heat it and...
  10. T

    Biasi heating a koi tank

    :shock: is this covered by the domestic gas regs or the fishing tank ones :lol: :lol: i just hope the flow and returns are all pushed and locked together on the plastic pipework. come on guys anyone else got any weird stories of installs theyve been asked to do
  11. T

    magna clean

    how much for the lot inc machine? would you be able to post it too durham? and a receipt :shock:
  12. T

    Baxi 105e

    i had same probs before doing this tother engineers fit electrodes etc and i ended up changing pcb and it worked fine :shock: saying that i have had this fault on reverse polarity try a martindale tester on your socket to check for reverse polarity :wink:
  13. T

    apprentices

    i was approcahed by a youngun yesterday 3rd yr apprentice needs to work with some one to complete his gas portfolio i may give him a few days here and there when busy and pay him cash in hand :shock:
  14. T

    apprentices

    ive only been up and running 3-4 weeks but i could surely use a 2nd pair of hands, BUT im wary in case i cant pay them if im quiet. i know a young lad through a mutual friend who is 2 yrs into an apprenticeship but hes getting laid off as his employer now has to pay the 80 quid a week for him...
  15. T

    magna clean

    surely wanging a powerflush into the job is gunna make even a combi swap into a 2 day job :shock: customer wont like the prices of that
  16. T

    magna clean

    cw mains usually for me but im pricing magna cleans into price to hopefully maintain the system and chb guarantee :wink: ive heard the magna clean filters for powerflushing machines are meant to be TOP class :wink:
  17. T

    magna clean

    using a machine or mains pressure to flush the system ?
  18. T

    Scalewatcher

    when did they stop letting you putting pipework into the sides of combi mates.. i see you can only pipe them from the top or bottom or both
  19. T

    ferolli optimax he

    anyone fitting these boilers, a friend of mine is a rep for them and im installing one for a mutual friend of ours. apparently it has a 5 yr guarantee and is an ok boiler. any thoughts on them :wink:
Back