Search results

  1. D

    Help desperately needed - replacing light switches

    The intact switch has 8 terminals, none of which are marked with COM, L, L1 or L2! 6 terminals are taken up with 3 blue and 3 yellow, there is a red in terminal 7 and terminal 8 is empty. The spare two red wires are connected via a terminal block. The new 1G switch has 3 terminals, L, L1 and...
  2. D

    Help desperately needed - replacing light switches

    Hi, really need some help please with what I thought would be a simple job! I'm replacing three switches that control the hallway and landing light, a 1G 2W in the hall, and 2 x 2G 2W, one at the foot of the stairs and another upstairs. Both the 2G 2W switches control the upstairs landing...
  3. D

    Low water pressure/no water at all from bleed valve

    Does that mean accessing the manifold to unblock it? Or might flushing the system clear it?
  4. D

    Low water pressure/no water at all from bleed valve

    Can anyone explain this? I tried bleeding a cold rad this morning (expecting there to be air in the system) but when I opened the bleed valve only a trickle of water came out (no air). So I closed the lockshield valve expecting the water pressure to increase, but instead the water stopped...
  5. D

    Has the motorised valve gone?

    As a famous meerkat once said .....ssshhhimple :wink: Many thanks for the very detailed instructions! Very much appreciated.
  6. D

    Has the motorised valve gone?

    errr..... no. Some plumber he was! He was the same plumber who left the lockshield valves fully open on 4 of the rads. I've never done a mains flush on a vented system so would be grateful for any tips! :)
  7. D

    Has the motorised valve gone?

    It's open vented and the header tank is filling the system up ok. Apparantly another plumber changed a towel rad last year and when he took the old one off he was covered in a flood of black sludge! I suspect there may be blockages somewhere in the system. Is the only solution to have to...
  8. D

    Has the motorised valve gone?

    Help needed please! My uncle's house has 11 rads fed via microbore, a brand new Grundfos 15-16-130 pump and a 15-20 year old Potterton Netaheat boiler (serviced every year and heats water ok). Few weeks ago he asked me to look at a non-working rad in the bathroom. I noticed the lockshield...
  9. D

    Best way to heat a shower room

    Hi all, some advice needed please. I had an extension on the house this year which included a shower/toilet room (measures 8m3 with three external walls). I didn't bother plumbing a wet radiator in as I did not believe my boiler would handle any more (it's a Glowworm 30cxi with 9 radiators on...
  10. D

    Adding a PIR and a double switch to an existing light/switch

    Thanks for the quick reply. I only have one cable coming into the original switch, with brown, blue and earth wires. I should have said I am actually replacing a damaged PIR with a new one, but this time am fitting a double switch to replace a very dodgy 3 pin plug that the previous...
  11. D

    Adding a PIR and a double switch to an existing light/switch

    Hi I've been trying to find a previous thread to help me on this but failed! I currently have a single light switch in my garage to operate a fluorescent tube, wired with a twin (blue and brown) and earth. I want to add an external PIR light and swap the single switch to a double so that I...
  12. D

    Periodic Inspection and Test - What's it all about?

    Thanks for your comments guys, very much appreciated. I'm now waiting for the company boss to come back to me with his views on my observations :wink:
  13. D

    Periodic Inspection and Test - What's it all about?

    Right chaps, here's the situation. Had the guys in Saturday to complete the electrics on the new extension. They replaced 2 old fuseboxes with a new consumer unit for the whole house (charge - £300, which seems fair) and then carried out the PIR (charge £150). I estimate the total time spent...
  14. D

    Periodic Inspection and Test - What's it all about?

    Hi guys, thanks for your input. One final question, which is hopefully a simple yes or no answer, should the guy carrying out the PIR test every single electrical socket and light fitting in the house? Thanks.
  15. D

    Periodic Inspection and Test - What's it all about?

    The PIR is for a small extension I am having on the house and the company I have asked to do the electrics said it would be wise to have one done (the property is 200 years old if that makes any difference). It seems like a good thing to have as "peace of mind"? The house is detached, has 3...
  16. D

    Periodic Inspection and Test - What's it all about?

    Hi I've just had a quote of £150+VAT from a company to carry out a Periodic Inspection and Test on Existing Circuitry and I have a couple of questions which I would very much appreciate someone answering:- 1. Is this a fair price? 2. What exactly should they do for this fee? 3. How long...
  17. D

    Boxing in an Air Admittance Valve

    Thanks for the tips guys.
  18. D

    Boxing in an Air Admittance Valve

    Hi Just had to fit a 1m high air admittance valve next to the toilet in a newly built shower/toilet room. However, it looks pretty ugly so I want to box it in with some MDF, but will that affect how it works? Any advice is appreciated. Cheers
  19. D

    Garden Lights

    Hi All Thanks for the tips. RCD sorted, 5a fuse in the plug and have used 3-core SWA too, buried a foot underground. Looks the biz! Cheers dirty harry
  20. D

    Garden Lights

    Hi, some advice please. I am rigging up 8 garden spotlights, each one has an 80w PAR38 bulb. However, I want to "daisy-chain" them together so that I am left with only one plug at the end to go into the mains supply. My question is, what size fuse should I use for the plug? Cheers...