Search results

  1. P

    Outdoor Connector

    Hi I have an outdoor transformer with this connection . Where can I get a connector for this transformer? Many thanks
  2. P

    Photocell

    Hi all, I have heard people say that photocells like http://cpc.farnell.com/1/1/111838-ip54-sunset-switch-epsswb-smj-electrical.html are not suitable for LED lighting. What would happen if one of these photocells were used to switch an outdoor led light string and a wicks Eton garden light kit...
  3. P

    Linking sockets

    Hi not too sure as to what is used to connect metal clad sockets together that are no more than 5cm apart? I have seen conduit used for this but am not too sure as to using adaptors etc. when doing it? It is PVC conduit. Thanks
  4. P

    Grid switch

    I just wasn't sure if it was bad practice or not. Anyway, thanks for all your helpful replies.
  5. P

    Grid switch

    I am aware of all fuse ratings and what size twin and earth to use but i've only ever seen flex in a batten holder. Is T+E alright to connect from the grid switch through conduit and connect to the batten holder? Probably sounds silly but it's just my experience with them
  6. P

    Grid switch

    Wired in 1mm T+E?
  7. P

    Grid switch

    This is just an odd job for a friend. So is the answer to use 1mm T+E from the switch and connect to the batten holder? I've only ever seen flex connected to a batten holder.
  8. P

    Grid switch

    Hi all I have a client that wants a grid switch installed in an outbuilding for a light. It is a 2 gang switch with a fuse as it is fed from a socket. The cable from the socket to the fuse is 2.5mm twin and earth and also from the fuse to the light switch next to it. PVC conduit will run from...
  9. P

    Male and female adaptors

    Thanks very much
  10. P

    Male and female adaptors

    Hi are male adaptors or female adaptors easier to fit and what tools are required to fit them? Thanks
  11. P

    Outdoor security light

    ok thanks
  12. P

    Outdoor security light

    Is it better to replace the run with flex?
  13. P

    Outdoor security light

    Hi there is an existing outdoor light with PIR on a wall, but is switched from inside the house as there is no lux sensor to prevent the light from activating during the day. They want a photocell sensor fitted to switch it automatically but the cable going to the light is via twin and earth...
  14. P

    Wall light flex

    Ok thanks everyone
  15. P

    Wall light flex

    The lights are individually switched so would it be okay to exit the two flexes through the flex outlet on the same fcu? The lights have 2 core flex and are Class II Regards
  16. P

    Wall light flex

    It would be a 3A
  17. P

    Wall light flex

    Is it suitable to wire 0.75mm flex from 2 wall lights into one FCU spurred off the ring, or would they have both have to go to separate FCUs? Thanks
  18. P

    Compression gland

    Thanks everyone
  19. P

    Compression gland

    Thanks what method is used for biting them down?
  20. P

    Compression gland

    Hi What compression gland is suitable for use with 2.5mm flex? Thanks