Search results

  1. R

    Texecom Premier 48 bringing up to date?

    Hi, thought I would post an update. New alarm box fitted, was pretty straightforward on the cabling front, copy and paste. I was able to reference the old Wintex profile to set up the new profile, so bulk of the heavy lifting was already done. I did hit little issues one after the other but...
  2. R

    Texecom Wintex Issue

    Wrong thread
  3. R

    Texecom Premier 48 bringing up to date?

    That was it, the code was different. You are a star!! Many thanks. Let the fun begin...
  4. R

    Texecom Premier 48 bringing up to date?

    Yes, I'm able to enter that on the keypad hence not setting off the tamper switch on the cover.
  5. R

    Texecom Premier 48 bringing up to date?

    Right, I am trying to connect to my existing panel, Premier 48. Usb cable connected to com1 on the panel (it has com1 and com2). Drivers installed for the cable and configured on the laptop as com1. In Wintex I have created an account, selected Premier 48, software version 8.x (as per my...
  6. R

    Texecom Premier 48 bringing up to date?

    Thanks, that was the ticket: https://branding.texe.com I think I had an old account, I was able to reset the password here and download it.
  7. R

    Texecom Premier 48 bringing up to date?

    Cable arrived, the new equipment will arrive in the next day or so. I've been looking to download Wintex, on the Texecom site it sends me to sign up to Texecom Cloud which I can't as an end user and don't have a company or vat registered. I looked to sign up to...
  8. R

    Texecom Premier 48 bringing up to date?

    Ok, will do. There's not much in it. Cheers
  9. R

    Texecom Premier 48 bringing up to date?

    Thanks for this information. I won't get the flasher in that case, looking online I'll make my own usb cable following these steps too: https://cybergibbons.com/alarms-2/programming-a-texecom-premier-elite-12-w-using-a-ftdi-cable/ I also won't get the Elite 48, I'll get the 24 as I have 15...
  10. R

    Texecom Premier 48 bringing up to date?

    Pics of pcb. I found the expander in the loft as you suggested.
  11. R

    Texecom Premier 48 bringing up to date?

    Pic attached. I'll get to the PCB tomorrow and also take a look in the loft.
  12. R

    Texecom Premier 48 bringing up to date?

    Looking up the 8xp, I can see it's an external box as per the pic. I don't have such a box so assumed it was a circuit that sits inside the case, a pic of my alarm attached.
  13. R

    Texecom Premier 48 bringing up to date?

    Hi, I've spent a bit of time this evening and I believe I need the following, would you be kind enough to review and feedback? Texecom Premier Elite 48 Backup battery Premier Elite RM8 expander - Can I use the existing expander one off my Premier 48? SmartCom CEL0001 Flasher Interface CDH-0001...
  14. R

    Texecom Premier 48 bringing up to date?

    Thanks, that is a good point. When I order the new kit, I'll get the cable to connect to my computer and I'll take screenshots of the existing setup. I'll see if I can put a list of components/ kit together today.
  15. R

    Texecom Premier 48 bringing up to date?

    Seeing as most of the system is there, how difficult would it be for me to DIY install? I'm fairly handy, can I just copy and paste the existing installation? My existing system is metal cased, I wonder if you can replace just the pcb for the newer model. I'm just thinking out aloud.
  16. R

    Texecom Premier 48 bringing up to date?

    Thanks for replying, good to know I can utilise some of the kit I currently have. Can I keep my existing keypads? They're brushed steel type so hoping I can
  17. R

    Texecom Premier 48 bringing up to date?

    Hi, I have a Texecom Premier 48 alarm system that was fitted in 2011. The keypad shows firmware v8.13. It has the dialler (don't think it works), 8 pir sensors, 6 surface mounted door sensors, 1 garage door contact , 2 keypads (hallway and garage). All hard wired. Is it possible to update...
  18. R

    Unvented cylinder not providing hot water to sinks,only showers

    Thanks, I'll try and figure out the function of that isolator and see what else there may be lurking around that pipework.
  19. R

    Unvented cylinder not providing hot water to sinks,only showers

    Turned off that isolator and let the showers run, hot and cold and didn't see any difference. The hot runs hot and cold runs cold, no difference in pressure or flow
  20. R

    Unvented cylinder not providing hot water to sinks,only showers

    Some more pics, yes the isolating valve is on the balanced cold pipe with red handle.
Back