    Possible flue fault

    Sounds like they sent me a right clown then cause he told me to do it myself and save money, he even left me a couple of little metal clamps.. I'm thinking i may report him.. Thanks for that .. should i be concerned about boiler not igniting first time ???
  2. H

    Possible flue fault

    No joke mate, though i'm thinking he was a bit of a joker. He made his diagnosis without even looking at flue, and guess what, the flue's the only thing thats not coverd.. you got any ideas ..
  3. H

    Possible flue fault

    Hi all, i have an Alpha CB24 Combi Boiler, it's approx 5 years old. I noticed towards the end of last winter that when boiler fired up to heat rads it would ignite 2 or 3 times before it fired up and stayed on, i didn't worry to much as the heating was working ok and hot water was also ok. i've...
  4. H

    USB Not Working..

    I've been on ASUS and NVIDIA but to be honest im not sure what i'm looking for. My motherboard is an ASUS A7N8X2.0, NVIDIA NForce series 2 ??? Can't find either of these...
  5. H

    USB Not Working..

    yes, tried to restore to various times and dates but it fails everytime..
  6. H

    USB Not Working..

    Have had a problem with usb not recognisng new devices for sometime now. Wizard searches for drivers but never finds them. Devices show in device manager with a yellow ! . All devices that have been working on usb in the past still work ok when connected, problem is just when trying to add new...
  7. H

    Smelly cold water.

    Yes mate, 2 copper pipes coming up from floor that change to flexi house, about 12 inch long each. they then change back to smaller copper pipes as they approach underneath of basin.
  8. H

    Smelly cold water.

    Definatley no cold water storage tank in loft, or anywhere else in house.
  9. H

    Smelly cold water.

    sink and bath water coming from same feed and i believe they are mains fed. No stored water or tanks anywhere, just combi boiler in airing cupboard. The bathroom sink is probably the closest to boiler but as i said its only cold water so surely this is coming straight from main supply ??
  10. H

    Smelly cold water.

    Hi all, i had a new bath sweet fitted just over 12 months ago and up untill now everything has been fine. However i recently noticed a bad smell coming from the cold water in sink. Hot and cold run out of same tap,i think its called a monoblock, and all is ok when running hot water but when you...
  11. H

    usb drivers

    Have recently bought a webcam, software installed no problem and pc responded when usb lead connected but wizard could not find drivers. I returned webcam to store and bought a different model but still getting same problem. The model i now have is Philips SPC230NC, when i look in device...
  12. H

    Wiring advice.

    There is a Termianl 4 in stat but its not being used. The wiring inside stat has never been touched.It was working old boiler so i know that side is ok. I'm just hoping we got the 2 lives correct at the boiler end. Thanks for your time .. :) :)
  13. H

    Wiring advice.

    Ok, i'm 99% confident that the 2 wires already connected are the live and live switch and that they are connected right way around. I will connect the spare wire to the neutral on boiler and see what happens... Might leave it untill tommorrow though :lol: :lol:
  14. H

    Wiring advice.

    Thanks for your reply. So from what i understand my stat is connected correctly,live in-live out. But i need to connect the neutral asap our else it will damage stat and heating will not function correctly. :?: :?:
  15. H

    Wiring advice.

    So if i read this correctly.Terminal 3 on stat is switched live and should go to position 1 on boiler.Terminal 1 on stat is live and goes to position 2 on boiler,which is as it is .Terminal 2 on stat is neutral and i have got to connect this to the neutral on feed to boiler?? What difference...
  16. H

    Wiring advice.

    Thanks for your replys Steve,just checked all wiring from stat. cable connected to 1 in thermostat runs to 2 on boiler.Cable connected to 3 on stat runs to 1 on boiler and connection 2 on stat is not connected to anything on boiler. Problem is i dont understand mini diagram inside stat cover...
  17. H

    Room Stat, Confused..

    I have 8 radiators in total. When heating first comes on boiler fires up and stays on for approx 4-5 mins.It will then go off for about 60 seconds and come back on again. When it comes back on its normally on for around 2-3 minutes then it goes off for 1-2 minutes and does this repeatedly...
  18. H

    Wiring advice.

    Boiler is a Alpha CB24X Combi. Front panel on boiler has 2 stats,1 for water,1 for heating. There is a timer switch also. I have to unscrew front panel for it to drop down and there are 2 connection blocks.1 to power boiler and 1 to power room stat. The room stat is a honeywell,model unknown...
  19. H

    Wiring advice.

    Need some advice on wiring a room stat.Stat is already fitted but was not connected to new boiler.Inside stat has 3 wires,Red-1 Blue-2 Yellow-3. Problem i have is boiler only has a A and B connection on it. I had a freind connect it for me but i'm not sure its working correctly. Can anyone...
  20. H

    Room Stat, Confused..

    I did as suggested and turned boiler control upto 6,room stat was left at 19. All this did was make the radiators get hotter why they were on.Boiler itself still switches on when room stat clicks but then just trips on and off every couple of minutes as stated before untill it eventually decides...