Search results

  1. A

    Rats soil waste pipe

    It's been 48 hours since I fitted the rat flap and so far the CCTV has not captured any rat activity, I think it's safe to say the rats have been entering via the ground floor WC waste pipe. I purchased a cheap inspection camera which connects to your phone and managed to get the camera below...
  2. A

    Rats soil waste pipe

    After several days of monitoring via the CCTV camera, I am pretty certain that the rats are entering the suspended floor via the ground floor WC as they are constantly returning to the area where the WC is located. They are huge and clever, I laid down a rat trap underneath the suspended floor...
  3. A

    Rats soil waste pipe

    Looks like I may have missed the mark :( Just past 4am the CCTV camera triggered a recording and captured footage of the rat, sniffed around for a few seconds before disappearing underneath the floorboards. Pic attached It appears it's come through elsewhere, not the hole I suspected! We...
  4. A

    Rats soil waste pipe

    Update I've excavated more of the area, removing the expanding foam and can see a deep hole in the corner which passes beyond the brick work of my property. Upon closer inspection I can also see the waste pipe which connects to the man hole in my neighbours garage! I've tried to open my...
  5. A

    Rats soil waste pipe

    I've been hearing noises for the past several weeks and finally suspect the rats are getting in via the soil waste stack as I could hear the noise coming from the base of the stack. Pics attached I removed the floorboards and at the base of the stack I could see droppings and a pungent smell...
  6. A

    uPVC door adjustment help

    Update Lowered the striker plate strip approx 7mm, door now locks perfectly! If you're hinge doesn't have height adjustment this could be a solution for others that may encounter a similar issue
  7. A

    uPVC door adjustment help

    As I can't raise the height of the door, I need to lower the striker plate so it aligns with the door. Raising the striker plate won't work as I can't adjust the door
  8. A

    uPVC door adjustment help

    I'd say the hinge side, as soon as I lift the door it engages and locks fine, otherwise it doesn't lock. Thinking to either pack the hinge or lower the striker plate
  9. A

    uPVC door adjustment help

    Had a look, the bottom is just for compression Need to adjust height approx 10 -15mm what would be the past way to do this? Can you add packers to the hinge?
  10. A

    uPVC door adjustment help

    True! I think the door has dropped, hence why it is catching, how can you adjust the height?
  11. A

    uPVC door adjustment help

    I'll give it a go, making small adjustments as I go and test it as I go along, will report back. Didn't realise until later that rosewood coloured doors are notoriously problematic when it gets hot. White doors never had a problem! Many thanks!
  12. A

    uPVC door adjustment help

    So all i need to do is adjust the allen bolt, given that the door is catching against the frame and difficult to engage the lock I will need to adjust the bolt clockwise? I do hope this works I'm at my wits end, looking at the metal strip, the strike plates are all over the place, they are not...
  13. A

    uPVC door adjustment help

    We've had several locksmiths out paying a small fortune over the years but whenever we have hot weather the door starts to play up! The door is catching against the frame and we are having to exert a lot of force to lift the handle up in order to lock the door, to the point where I think we'll...
  14. A

    Fence height regs enforcement

    Planning on installing the fence this summer, I mentioned I'm intending to install a 6ft fence with a 1ft gravel board. Problem is, I would be 13cm over the 2m regulations. My plan is to therefore bury 13cm of the concrete gravel board into the ground and then backfill with soil to ensure I'm...
  15. A

    Reliable outdoor wall light

    Currently have an outdoor light which is PIR only but very unreliable and temperamental. I've had a few which have all been the same. Does anyone have any recommendations for a reliable/ heavy duty commercial spec if needs be (for domestic use) photocell and PIR outdoor light which is dimmable?
  16. A

    Black tar leak electric meter

    I just hope it's not dangerous and not a risk of causing a fire! What would cause the noise and for it to leak tar?
  17. A

    Black tar leak electric meter

    Earliest I can do it will be on the weekend as away, what would be the noise? Is it dangerous?
  18. A

    Black tar leak electric meter

    Yep, only when very close to it I can hear a screeching sound
  19. A

    Black tar leak electric meter

    Black tar is leaking from the electric meter running down along the pole, is this normal? It doesn't smell and is not hot.
  20. A

    Gas smell from boiler after switching off CH

    So the PRV was replaced today the copper prv discharge pipe was full of crud! Engineer cleaned it as best as he could. So far all appears to be fine, although I can still see a slight drip on the PRV pipe outside, hoping it's just residual water!
Back
Top