Search results

  1. O

    Supplementary bonding in a bathroom (sorry!)

    Thanks for taking the time to reply to my dumb question!!! :) So just to be clear (sorry its saturday night and this is all i can thing about!!!!) In my example the shower would require no further bonding other than the supplementary bonding i've already carried out?
  2. O

    Supplementary bonding in a bathroom (sorry!)

    I have searched through the archived threads looking for a definitive answer to a question thats really bugging me. To be honest though i'm now more confused than ever!!! Imagine the scene 25mm2 Meter Tails 16mm2 Main Earth Conductor 10mm2 Main Equipotential Earthing conductors...
  3. O

    Zones and surface mount trunking

    Brillant thank you!!!!! I thought i'd read the regs right but i had a building control guy telling me it had to be in safe zone regardless. Thanks for the reply
  4. O

    Zones and surface mount trunking

    Wondered if you guys might be able to help me. Do the rules for running cables within safe zones apply to surface mounting plastic trunking or conduit? I know that if the cable is run outside a safe zone its supposed to be placed at least 50mm deep and mechanically protected, but does this...
  5. O

    Circuit for alarm

    yeah thats what i figured, i just wanted to make sure i wasn't barking up the wrong tree!!!!! thanks for the reply
  6. O

    Circuit for alarm

    Hi, i wanted to ask for an opinion!!!! I'm just about to add a seperate circuit to power my home alarm system (at present its run off a spur from the ring) I'm just going to run a radial circuit to a sw/fcu (for isolation) and then power the alarm from that. my question is.... As the...
  7. O

    RCD Tripping times

    how about a fiver?
  8. O

    Electrical socket in bathroom

    common sense? madness!!!! :D
  9. O

    Electrical socket in bathroom

    [/url] are the sockets protected by an RCD or anything? Or are the germans just hard? ;)
  10. O

    RCD Tripping times

    i'm really pleased with the replies as they make total sense to me, i was worried i'd got a 7671 with missing pages or something!!!! ;-) The guy was so certain (to the point of arguing) that he was right i started to doubt myself
  11. O

    RCD Tripping times

    thank you, you've said exactly what i thought. This guy was so certain though that "100% of the time" the 100mA would go first i thought i was missing something. i just stood there quoting regs at him about 5 times I delta N disconnection times and all that, he just kept saying yes yes but...
  12. O

    RCD Tripping times

    I've just had a long conversation with a NICEIC inspector regarding which RCD out of a 30mA and a 100mA would trip with a fault current first? Now maybe i've just gone mental or something but everything i know points me towards the idea that the 30mA would trip first, however the guy from the...
  13. O

    Best way to remove tiles?

    yeah i wouldn't want the hut to get damaged!!!!!
  14. O

    Electrical socket in bathroom

    i thought the only socket outlets allowed in a bathroom were SELV or shaver sockets?
  15. O

    Electrical socket in bathroom

    is some of your post missing mate? the section that ends with "it used to po" :)
  16. O

    Best way to remove tiles?

    Thanks for the advice, i admit i should have searched the site first and was just being a little lazy! Thanks again
  17. O

    Best way to remove tiles?

    Hi there i wondered if anyone could help me, i'm about to start removing the tiles in an area in my kitchen (so i can chase the wall out for some electrical work) and wondered if there is a simple way to remove the tiles. Thanks in advance
  18. O

    13amp cooker plug???

    the big question is whats the wattage of the cooker?