  1. P

    Motorised valve won’t respond to hive

    Try pressing the central heating override button on the hive receiver and see if the valve opens.
  2. P

    S Plan to support Opentherm - TADO smart thermostat EU model

    Not sure about the OT but weather comp on pdhw is doable although you might have to change the c/heating 2 port head for a normally open.
  3. P

    New house - heating/ wiring help?!

    Looks like an old low loss header, the wire was a ntc sensor to control the temp of the header.
  4. P

    Saniflo running on noise with video

    Sounds like the flow switch is stuck on, it’s usually the rubber diaphragm that gets stiff with accumulated “stuff” and you can clean or replace.
  5. P

    Renovating 3 bed flat with 8/10mm pipes. Worth changing to 15/22mm ?

    I changed my way of plumbing flats to prevent leaks under the floor, I now run 15mm pipes from a manifold under the boiler to each rad, uses a bit more pipe but your not digging the floors up in a couple of years trying to find out why the ceiling downstairs has water dripping through it.
  6. P

    NEST Y PLAN

    You should not have 240 on the grey when calling for hot water only, you have either miswired it (most likely scenario) or a faulty nest.
  7. P

    DHW too hot in new shower

    Chances are the hot and cold to the shower are the wrong way round.
  8. P

    Replacing 3 gang 2way switch with smart one.

    And you thanked ericmark for this ?:rolleyes:
  9. P

    Replacing 3 gang 2way switch with smart one.

    I dont know of any smart switches that will work with ordinary switches, if you change all the switches to smart switches there are plenty on the market that can do this.
  10. P

    S plan / bypass gate valve / pump gone

    You dont need a bypass so the gate valve should be closed or got rid of.
  11. P

    Replacing 3 gang 2way switch with smart one.

    No you cant use the smart switch as it does not have two way switching.
  12. P

    Replacing 3 gang 2way switch with smart one.

    Yes but are they attached at the other end ? what is the make and model of your smart switch ?
  13. P

    Replacing 3 gang 2way switch with smart one.

    The most obvious question is do you have a neutral at the light switch ? your smart switch needs it to work.
  14. P

    Is this the norm now days

    Might be a good idea to find out the kw rating for the oven before giving advice.
  15. P

    New Combi or Unvented Cylinder

    So your system was installed before unvented cylinders were allowed , no one would expect you to rip out a serviceable cylinder for no reason but there will always be luddites.:cool:
  16. P

    New Combi or Unvented Cylinder

    Poor pressure through out the house (unless you put a pump in) dead things in the loft tank if the lid gets knocked, frozen pipes in the loft that flood your house when they thaw, versus Clean fresh water at all taps, good pressure for shower / quick bath filling and no pipes in loft, quite...
  17. P

    New Combi or Unvented Cylinder

    Maybe you could explain how a vented cylinder is more "efficient" with long pipe runs than an unvented cylinder ?
  18. P

    New Combi or Unvented Cylinder

    Nobody in their right mind would choose to install a vented cylinder from scratch, 18kw if fine with a 250ltr cylinder.
  19. P

    Unvented cylinder install - help!

    Ah ok then all's good.
  20. P

    Unvented cylinder install - help!

    Install looks fine but I would ask for an isolation valve to be fitted, the fitting aren't pushfit they are pressfit and ok being used on your pipework.