  1. C

    Greenstar 25i erp pressure gauge

    Very simple question regarding the water pressure gauge on a Greenstar i25 erp boiler. I went to view a property for sale today and noticed that the pressure gauge was showing 0. The boiler itself was working (heating and hot water) but can someone please confirm my thoughts which are that the...
  2. C

    Mixer tap screw handle removal

    Based on another set of taps that I have (I think they are both Sottini), the cap unscrews. On the other set, when I replaced the cartridge a few years ago I applied grease to the thread and I was able (today) to unscrew the cap. It's a really poor design meaning (unless there is a trick I don't...
  3. C

    Mixer tap screw handle removal

    I need to replace the cartridge on a mixer tap but need to unscrew the small metal cap at the top of the handle to get to the grub screw. The cap won't move under hand pressure and there is very little metal to grip so does anyone have a trick to removing these without breaking the ceramic?
  4. C

    Meter Tail Clamps

    Thanks sparkymarka - I saw singles but couldn't find any doubles!!!
  5. C

    Meter Tail Clamps

    No not the stuffing gland, I mean clamps to tidy/hold the tails on the wooden back board. I was told before that although these were not an absolute requirement, it was best practise. The photo below is not exactly what I'm after (these obviously wouldn't affix to a backboard) but hopefully is...
  6. C

    Meter Tail Clamps

    Really simple question this one! I'm installing a new consumer unit (under building control) and need a couple of clamps for the tails but can't seem to find them anywhere (looked on eBay, Toolstation, CEF, TLC.). Can someone please point me in the right direction as I would think these must be...
  7. C

    32mm incoming mains supply - reduce to 22mm or 15mm

    Thanks Madrab - very interesting/useful information. It's only a small/medium sized 3 bedroom house (which will be rented out) so I don't think it's unreasonable for people to stagger their water demand. I will heed the advice and use 22mm up to the point where it need to split off.
  8. C

    32mm incoming mains supply - reduce to 22mm or 15mm

    Thanks both. There are two bathrooms and three toilets. Rightly or wrongly, I've already plumbed the bathrooms/toilets in 15mm but haven't completed the run from the boiler to the first bathroom (the second bathroom tees off from the first) or kitchen. I can therefore run in 22mm up to the...
  9. C

    32mm incoming mains supply - reduce to 22mm or 15mm

    I have a new 32mm incoming water supply which terminates directly below where my new boiler will be located. My thoughts are that I should reduce from 32mm down to 22mm and then where I tee off for the boiler, I use a reducing tee to provide a 15mm feed for the boiler and another 15mm feed for...
  10. C

    GoSystem QP8088H Auto Power or QP8937H Auto Swirl?

    I've decided to buy myself a new torch and need it for both general plumbing work (I am not a plumber but am refurbishing a house and do my own pipework) and I have just got into the world of stationary engines so I want to be able to undertake brazing work on those. I think the GoSystem QP8088H...
  11. C

    Light Fitting Resonance!

    I understand what you are saying but the "buzz" moves from lamp holder to lamp holder and disappears if all lamps are removed. It's also much quieter than a "normal" arcing sound.
  12. C

    Light Fitting Resonance!

    Apologies for the delay - am abroad at the moment. Difficult to say exactly but I would say it is probably a 50Hz frequency. The sound appears to be emanating from inside the fitting. It's not really a problem as it is fairly quiet and now I have found a way to silence it by moving the lamps...
  13. C

    Light Fitting Resonance!

    I might have used the wrong term with resonance - possibly inductance. It is a large metal light so the metal may be picking up the mains (from memory I think the live is switched within the ceiling rose) and causing the fitting to vibrate/hum.
  14. C

    Light Fitting Resonance!

    Hello John. No, must have at least one lamp in to make a noise. It's definitely resonance of some sort I'm sure. What I don't understand is the inconsistency.
  15. C

    Light Fitting Resonance!

    So, had a little play today and found that with one particular fitting (chosen at random), if I removed the lamp then the sound started (in that fitting - buzzing sound). Replace the lamp (I tried two and it made no difference which one I used) and the sound stopped. Not sure if I would have...
  16. C

    Light Fitting Resonance!

    No problem. Yes I agree - very strange. I will have a little play and will post what I find.
  17. C

    Light Fitting Resonance!

    Hello John. Yes i did mention that it is a standard mechanical one way switch. Must surely be something to do with induction I think.
  18. C

    Light Fitting Resonance!

    John. I tried both the LED and halogen lamps and it made no difference I e with one lamp fitted of either type the noise was present. What I don't understand is why the noise has now gone just by me changing the position of the lamps. If I feel inclined, I might experiment further and move the...
  19. C

    Light Fitting Resonance!

    Ok, so, here is an update. Firstly, don't get too upset by the mix of different lamp types - this is a house I am completely gutting and extending so any lamp mix-match is temporary. The photo was taken with the light off so the halogen candle is a worker (the others are candle LEDs). There is...
  20. C

    Light Fitting Resonance!

    I have a light fitting (photo below) which is making a very low volume "buzzing" sound even when the lights are off. This changes slightly in pitch and volume when the lights are turned on. Really not sure what is going on as there are no electronics involved so I think it must be some form of...