Search results

  1. U

    Remeha Avanta 28c Advice

    Thanks for all your advice, I think i'll give one a try then .
  2. U

    Remeha Avanta 28c Advice

    Thanks Gremlin The reason i ask is because im going to rent out a flat and need a boiler that will give me minimal problems , did you say that the filling loop is built in .
  3. U

    Remeha Avanta 28c Advice

    Hi All Has anyone fitted or come across one of these, I need to know if they are reliable and easy to work on, are there any problems with them. Thanks
  4. U

    Flue too close

    Just a quick one, Have a vertical flue too close to an openable window , What would be put on the warning notice , AR or ID . Thanks
  5. U

    Hot Grundfos pump?

    How can you say "Nevertheless, I expect it was correct." when there is a 50% chance it wasnt .
  6. U

    Help - the dripping is driving me mad

    Does the water ever stop dripping ? If it does it should be a sign that you neighbours are at home and have flushed the toilet . Thats the time to start knocking on their door.
  7. U

    Hot Grundfos pump?

    Just a thought - if some rads aint getting hot , did you install the pump with the same flow direction as the one you took out ?
  8. U

    Heating pipes in concrete

    This is the stuff you need. http://www.hep2o.co.uk/v2Oconduit1.htm
  9. U

    Do I pay water rates at an unoccupied property??

    Might be easier in the future to get a meter installed, then if you dont use any water , you wont get a bill.
  10. U

    To flush or not to flush...

    Maybe you could use a wet/ dry hoover and suck out the F+E tank - sounds like its gone a bit mouldy.
  11. U

    Valiant Combi boiler

    A friend of mine had the same problem and was topping up system every other day. I told him he must have a visable leak somewhere. After weeks of him searching under floors and all the pipework and the pressure relief outlet pipe, I came to look and took off the inner boiler casing and found the...
  12. U

    Problem with danfoss wireless thermostat/receiver

    These have two battery compartments, one for the display and the other for the transmitter. For the cost of 4 AA batteries just change them.
  13. U

    combi boiler illegally installed?

    See page 18 of this Baxi manual foe flue sitings. http://www.baxi.co.uk/docs/Baxi_Combi_Instant_HE_Installation_and_Servicing_Instructions.pdf
  14. U

    two boilers on one system

    You would be able to just Tee into the flow and return near to the existing boiler and put some gate valves on both boilers so you can isolate either one .
  15. U

    Possible leaking hot water pipe under floors

    How about getting an infra red thermometer (about £30) and trying to locate the hottest area of the wall where the water would be leaking from ?
  16. U

    powermax 185 poss fault

    I had this fault on a powermax and it turned out to be the built in programmer not switching. Had to replace it .
  17. U

    low pressure on new bath/shower

    It could be the ballofix valves are the restriction. Fit full bore valves.
  18. U

    Thermostatic shower problems

    Are you sure it has been connected up correctly . ie hot and cold pipe the right way round . check that the hot pipe is connected to the side with the red dot on it. Its an easy mistake to assume that the old one was connected the same way.
  19. U

    what to use to cap the end of a washing machine valve

    if you;re just capping off the washing machine valves then you will need 3/4" iron caps and some ptfe tape .
  20. U

    Radiator manufacturer

    That def a STELRAD P+
Back