Search results

  1. Deelta

    Alpha CB24X

    Hi every one, the above boiler been off for few months we trying to put it on but the the two neon flashing which mean low pressure trying to fill it, but it does not show in the gauge, but you can hear the water going, no leak any where in the system, but I noticed that the RH side of the...
  2. Deelta

    Vaillant turboMAX plus 828e

    Hi every one, the problem with this boiler stops after few seconds, when switched on either for CH or DHW the boiler starts as normal but stops after a short time and the dispay showes F22 and an other time F24, the water pressure is ok and the system is full of water..any help please??
  3. Deelta

    Shower pump

    thanks for that, but they very costly, I think pressure reduce valve and a pump would be a good idea.
  4. Deelta

    Shower pump

    Hi every one, how can a shower pump to be used where the cold water from the main supply and the hot water from the tank as there is no way to bring the cold water from the tank, any suggistions please :?:
  5. Deelta

    Baxi Combi 80 Eco

    thanks folks, it is sorted, it was the sensor as it was checked first time with a faulty meter and when re-checked founded short circuit :D
  6. Deelta

    Baxi Combi 80 Eco

    the fan does not start at all, the only part running is the pump
  7. Deelta

    Baxi Combi 80 Eco

    thanks, the over heat stat ok, the micro switch ok the pump is running, any thing else to check?
  8. Deelta

    Baxi Combi 80 Eco

    Hi, this baxi 80 eco does not start at all in both hw & ch the only part running is the pump, Hi Limit stat ok no 240v at the fan, checked all the cables for continuity ok, pcb!!
  9. Deelta

    Worcester 240 BF

    Hi, any help please, it is a worcester 240 BF start to make a loud noise when you draw hot water only, on CH it is OK, any idea :?:
  10. Deelta

    Indesit WILD102

    Hi, I came this washing machine which does not drain the water, after cheching all the possible problem I found that the pump OK and when the supply leads off the pump it does read 240V but once I plug the leads back in to the pump the reading is 0V but the live is there, the problem started...
  11. Deelta

    Jaguar 23kW

    Hi every one, I have been to see this Jaguar boiler, I think I know what is the problem but I just want to make sure, once you switch it on from the mains switch the boiler starts and the DHW LED comes on but the heating is on and it want goes off by pressing the the off button and only by...
  12. Deelta

    Water from vent pipe

    canb't see FAQ
  13. Deelta

    Water from vent pipe

    Hi, it is one of the old systems but it did work for years, anyway, the system is a fully pumped one and works with one switch i.e water and heating, it was off for some times and then start to make a noise and found the pump is almost gone so change it to a new one make sure all the valve open...
  14. Deelta

    Biasi 24S

    yes there is 240V on the two wires for the ignition pcb
  15. Deelta

    Biasi 24S

    that is what biasi tech told me, anyway, looking at the main PCB there is two connectors to the right, the first one where the mains in the second one there are 4 wires Br/Bl Bl/Br there is 240V between the two Bl, the o/h is close circuit and the APS is ok, so he told me the Black/Red ignition...
  16. Deelta

    Biasi 24S

    over heat stat OK, according to Biasi and after some voltage checking is the ignition box on the gas valve, still hasn't been replace waiting for it.
  17. Deelta

    Biasi 24S

    Any help, the biasi 24S boiler does not work DHW or CH, the only part is going the pump only, there is no 240V on the fan, what could it be?
  18. Deelta

    Eurocombi A23 MFFI

    A problem with the above boiler, when you ask for HW or CH the boiler starts and stops and starts and stops few times and works for some times and starts the same thing again and again, I can hear the relays clicking on the RH PCB, what could it be :?:
  19. Deelta

    Microcombi 23MFFI

    Hi, a problem with this boiler it goes to lockout after few seconds on both CH & DHW reset and the same, the prob sensor looks fine, by the way the spark doesn't stop even when the burner is on, any help :?:
  20. Deelta

    Biasi M90E 24S

    you right i did mean to say the LEFT LED, on demand for DHW and/or CH the boiler does not start, pump or fan, it is only one pcb
Back
Top