Search results

  1. S

    Fitting an outside socket for charging hybrid car

    Hi again flameport....apologies for the delay and yet more questions As advised, i purchased an unswitched BG socket to swap into the housing, but as you can see from the pictures, the profile is significantly different and doesn't sit flush inside The switch that came with the outside socket...
  2. S

    Fitting an outside socket for charging hybrid car

    I really didn’t want any cables on show but I’m out of options now TIA
  3. S

    Fitting an outside socket for charging hybrid car

    Sorry for yet another question….. where sockets are in plasterboard stud wall and approx 6 inches above the skirting board, does/should the cable be in any sort of trunking, or is it ok to just poke up through the horizontal cardboard ?
  4. S

    Fitting an outside socket for charging hybrid car

    flameport : thanks for advice, i'll be sure to check beforehand 2 further questions (apologies) Q1 : Can you confirm if 25mm x 16mm trunking is suitable for running a single 2.5mm t&e please ? from what i can see its perfectly find as there is a percentage of "free space" required in trunking...
  5. S

    2.5mm t&e and telephone cable query

    I’ve had a flick through the above mentioned thread randomgrinch Seemed to get rather heated at times didn’t it ! Upshot is that will split them and put in their own trunking Ive got some 30mm D profile which aesthetically looks ok and seems that that is the minimum size that can be used for a...
  6. S

    2.5mm t&e and telephone cable query

    thanks for the reply Grinch i'll take a look at the thread shared likely before bedtime as i'm guessing it will put me to sleep so will save on the Ovaltine ;) regarding trunking, yes i could i suppose have an addition piece of trunking alongside but it'll look a mess appreciate that you are...
  7. S

    2.5mm t&e and telephone cable query

    Hi all...can anyone advise here please.... I need an outdoor electrical socket on the front of my house The easiest way way to achieve, is a new dedicated feed from the consumer unit to the socket, but this would mean from floor to ceiling (2.4m), the 2.5mm T&E cable and a telephone cable...
  8. S

    Is this an alkathene pipe ? Size ?

    thanks JohnD if my dad is correct in that when he closes the stop tap but the water doesn't shut off, what is that a sign of exactly ? is it just a rubber washer that has likely perished or summat else ? yes there is a stop cock at the end of his drive where we will isolate first (y)
  9. S

    Is this an alkathene pipe ? Size ?

    thanks Exedon....my use and mention of iron work was just a lazy attempt at referring to the metal work
  10. S

    Is this an alkathene pipe ? Size ?

    Denso exedon, thanks for replies I was assuming that the lower connection would be disturbed hence assuming that I’ll end up replacing the lot and also, just personally, I’ve never been a fan of a large iron work onto plastic/alkathene
  11. S

    Is this an alkathene pipe ? Size ?

    Happy new year all ! So my dad has just tried to turn the cold water off using the stop cock in his house to change a tap washer (no isolation valves) but evidently its not having the desired effect and the stop cock has now started to drip a little. I'm not surprised consider the stop cock is...
  12. S

    Fitting an outside socket for charging hybrid car

    Just one further point of clarification flameport if i may You mentioned early on in the thread : Would it be acceptable for me to lay the cable and do the donkey work and capture video evidence for his review (photos under the floor) and then he simply does the work on the cable work at the...
  13. S

    Fitting an outside socket for charging hybrid car

    good call.....thanks flameport will this be ok for the inside 20A isolation switch that was recommended ? MK Logic Plus 20A 1-Gang DP Control Switch White | Switches | Screwfix.com If so, is there any reason why i can't be fitted into a plasterboard stud wall using one of these : Appleby...
  14. S

    Fitting an outside socket for charging hybrid car

    Thanks again flameport ! I'll swap the socket for a unswitched one then (y)
  15. S

    Fitting an outside socket for charging hybrid car

    Hi flameport Can you confirm whether if the socket was switched, whether that would be a cause for a fail if NICEIC visit please based on what you mentioned regarding the possibility of overheating/failure ? Reason for asking is that i was looking for a more aesthetically pleasing socket as...
  16. S

    Fitting an outside socket for charging hybrid car

    flameport - can i ask why you specifically mention a single unswitched outlet outside please ? Also, what size of cable would be needed for this ? From outside socket to the consumer unit would be around 12m Thanks again for your input (y)
  17. S

    Fitting an outside socket for charging hybrid car

    flameport, thanks for the reply and apologies for the delay in responding So where i'm struggling with these additional electrical requirements, is with the fact that the car was supplied with that cable as shown in my photos and If there are other considerations other than the need for just a...
  18. S

    Fitting an outside socket for charging hybrid car

    ericmark...wow, thanks for the mega reply but i have to say, you lost me VERY early on ! :confused: i've added some photos of the supplied charging cable so not sure if anything there clarifies anything more for you
Back
Top